Sicherheit
Specification
Product specifications
Pre-installation information
Diagram showing minimum installation requirements.
Cutting templates
What's in the box
Product front
Contents:
1 x T2 Tap
1 x Baseplate (Standard or MonoFit)
1 x Drip Tray
1 x 1.0m x 6mm Insulated Water Pipe
1 x Connector Cable
1 x Earth Wire
1 x Waste Drain Pipe
1 x Fixings Set
1 x Baseplate Cutting Guide
1 x ProCore Unit
1 x Power Cord Set
1 x DeepSparkle Kit (Sparkling models only)
1 x Simple-fit Ventilation Kit
Product rear
Dimensions
How-to-install video
Installation
Installation requirements
Identify a suitable location for the ProCore® undercounter unit. It should be positioned within 1.0m of the tap, and within 2.0m of suitable services connections. Ensure to allow enough space for the Simple-fit Vent Kit which must be installed with the unit. See Pre-Installation guide here for full installation requirements before proceeding with installation.
We recommend using an installation kit, which includes everything needed to complete the installation.
You will need:
- Installation kit, including water block and filter. Your kit will depend on your requirements and model. See installation kit guide here.
- Water block
- Installation Kit
- Jigsaw
- Hole saw (MonoFit® models only)
- Cordless drill
- John Guest pipe cutters
- Adjustable spanner
- Side cutters
- Screwdriver
- Allen key set
- 1L measuring jug
Standard or MonoFit?
The first step of your installation will depend on your tap system. If you have a Standard tap system, begin with Section 1a. If you have a MonoFit tap system, proceed directly to Section 1b.
To start the installation of a standard T2 tap system, follow Section 1a.
To start the installation of a MonoFit tap system, proceed directly to Section 1b.
Section 1a - Installing a standard countertop tap system
Section 1b - Installing a MonoFit tap system
Section 2 - Installing the undercounter ProCore and Simple-Fit vent kit
This operation must only be carried out by trained staff.
Section 3 - Connecting the tap to the ProCore
CO2 bottle installation - Sparkling models only
How to use
Tap control panel
Illuminated indicators
How to dispense water
Maintenance & cleaning
Sanitisation guide
You will need
- Measuring jug
- Protective gloves
- Hydrogen Peroxide (H202 3%) food safe sanitising solution
- Service filter cartridge
- Sanitising wipes
- Water filter
Care and maintenance of tap finish
Advanced setup
Certain features can be adjusted by a trained installer as part of the product set up.
Advanced settings
Adjusting sparkling water flow rate
NOTE: Sparkling water flow rate factory setting = 1.8L (0.4 Gal) per minute MAX. This may need adjusting depending on inlet pressure. To do so follow below steps:
Sparkling models only
Advanced troubleshooting
Troubleshooting
Warning flash sequences
In the event of the warning triangle flashing please see the sequences below for diagnostics.
Emptying sparkling water
Technical information
T2 Chilled & Ambient circuit schematic
T2 Chilled & Sparkling circuit schematic
T2 Chilled, Sparkling & Ambient circuit schematic
T2 Chilled & Ambient water pathway
T2 Chilled & Sparkling Water Pathway
T2 Chilled, Sparkling & Ambient Water Pathway
Spares
ProCore exploded parts diagram
T2 exploded parts diagram
Safety critical spares
Temperaturfühler
Kongress-Solenoidwebstuhl
All-in-One-Sensorkabelbaum mit KK-Anschlüssen
E6 Kühl- und Umgebungs-Touch-Bedienfeld (HMI)
T2 Chilled & Sparkling Touch-Bedienfeldbaugruppe (HMI)
E6 Gekühlte, prickelnde und Umgebungs-Touch-Bedienfeldbaugruppe (HMI)
Einzelrückschlagventil 5/16" (8mm) PF
Einzelnes Rückschlagventil 1/4" Steckverbindung
Magnetspule 3/4" BSP 8mm PF
Solenoid 3/4” BSP 8mm UL
703237
2:1 Dosiermagnetventil 8 mm
2:1 Dispense Solenoid Valve 8mm UL
703235
3:1 Dosiermagnetventil 8 mm
3:1 Dispense Solenoid Valve 8mm UL
703236
PCBA-Hauptsteuerplatinenbaugruppe
Membran-Druckerhöhungspumpe – Sprudelwasserpumpe mit geringer Durchflussrate, 115 V
Membran-Druckerhöhungspumpe – Sprudelwasserpumpe mit geringer Durchflussrate, 230 V
Kühllüfter 24 V mit Kabelbaum
FS-16 Durchflussschalter
Cosmetic spares
Tropfschalengrill der T-Serie und E7 – Polierter Stahl
Tropfschalengrill der T-Serie und E7 – Schwarz beschichtet
T2 Wasserhahnauslass - Schwarz plattierter Edelstahl
T2 Wasserhahnauslauf - Polierter Edelstahl
Laminar Flow Auslass passend für T1/T2
ProCore-Türbaugruppe komplett
ProCore Linke Seitenwand
ProCore Rechte Seitenwand