Sécurité

This appliance can be used by adults and children aged 8 and above, as well as people with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, as long as they have been given instruction or supervision concerning the use of the appliance in a safe way and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be conducted by children.

The appliance shall only be maintained and repaired by authorized technicians who are properly trained and certified. The appliance should be isolated from the electricity supply before removal of any covers. Great care must be employed when working with high pressure carbon dioxide, and in no cases should the maximum operating pressure of 0.4MPa (4 bar) be exceeded.

  • The appliance must be placed upright on a flat horizontal surface.
  • The appliance must be kept away from sunlight, heat and moisture.
  • The appliance shall not be placed in lobbies or locations of egress or where it may obstruct exit access.
  • The appliance must be installed in an environment free of dust and corrosive/explosive gases.
  • The appliance is not suitable for installation in an area where a water jet could be used.
  • The appliance must not be installed where it is liable to freeze. If the unit is thought to be frozen it must not be switched on.
  • The appliance must maintain adequate mechanical stability when in use, during transportation, assembly, dismantling, scrapping and any other action.
  • The appliance must not be installed without a waterblock. Installing without a waterblock will invalidate warranty.
  • The appliance must have adequate ventilation. Installing the unit without the Simple-fit Vent Kit will invalidate the warranty.

WARNING: Keep ventilation openings in the appliance enclosure or in the built-in structure clear of obstruction.
WARNING: When positioning the appliance, ensure the supply cord is not trapped or damaged.
WARNING: Do not locate multiple portable socket-outlets or portable power supplies at the rear of the appliance.
WARNING: Increased risk of a leak could occur through improper handling, movement or use.

The appliance must be installed in accordance with the relevant requirements of:

  • The appropriate building regulations by application of either The Building Regulations (England and Wales), The Building Regulations (Scotland) or The Building Regulations (Northern Ireland). In territories other than those listed the local regulations in force must be complied with.
  • The Water Supply (Water Fittings) Regulations (England, Wales and Northern Ireland) or The Water Byelaws in Scotland.

This appliance is designed for dispensing drinking water in commercial and workplace environments, including:

  • Offices and corporate workplaces
  • Factories and industrial staff welfare areas
  • Hotels, hostels, and other hospitality environments
  • Public buildings such as schools, hospitals, and leisure facilities
  • Household environments and similar applications.

The appliance is suitable for providing chilled potable drinking water for employees, visitors, and guests.

The appliance is intended for indoor use only and must be installed and operated in accordance with the instructions provided in this manual.

Restrictions on Use
  • This appliance is not intended for heavy industrial use or continuous high-demand applications beyond its specified capacity.
  • It must only be used for dispensing potable (drinkable) water.
  • Do not use the appliance for any purpose other than that for which it is intended.
Message de sécurité R290

Le R290 est un gaz propane de qualité réfrigérante utilisé dans une large gamme d'unités de réfrigération commerciale et de climatisation. Propane de haute pureté, il a un faible impact environnemental et un potentiel de réchauffement global (PRG) nominal, ce qui signifie qu'il ne possède aucune propriété destructrice pour la couche d'ozone. Le R290 est également l'alternative hydrocarbonée préférée par l'Agence de Protection de l'Environnement (EPA), remplaçant des réfrigérants fluorocarbonés plus nocifs comme le R22, le R134a, le R404a et le R502. Les unités utilisant le R290 ne peuvent être entretenues et réparées que par des techniciens autorisés, correctement formés et certifiés.

Déchets d'appareils électriques

En tant que producteur soumis à la réglementation britannique WEEE, Borg and Overström respecte ses obligations de producteur en étant inscrit en tant que membre d'un schéma de conformité WEEE et en détenant un numéro d'enregistrement de producteur WEEE. Ce produit est conçu et fabriqué avec des matériaux pouvant être recyclés et réutilisés. Le symbole signifie que le produit doit être éliminé séparément des déchets ménagers en fin de vie.
Numéro d'enregistrement WEEE du producteur : WEE/KG0136ZT

Specification

Product specifications

230V

115V

Water options

Chilled, Sparkling and Ambient
*Your water options will vary depending on your model.

Chilled, Sparkling and Ambient
*Your water options will vary depending on your model.

Système

Système de refroidissement DryChill®
Technologie de refroidissement rapide hygiénique. Noyau en aluminium massif avec serpentin de refroidissement en acier inoxydable hygiénique. Utilise le gaz éco-réfrigérant R290.

Système de refroidissement DryChill®
Technologie de refroidissement rapide hygiénique. Noyau en aluminium massif avec serpentin de refroidissement en acier inoxydable hygiénique. Utilise le gaz éco-réfrigérant R290.

Hygiène

Totalité
Méthodologie d'hygiène en 5 étapes

Viovandt (modèles sélectionnés uniquement)
Technologie LED UV-C écologique

Totalité
Méthodologie d'hygiène en 5 étapes

Viovandt (modèles sélectionnés uniquement)
Technologie LED UV-C écologique

Technology

DeepSparkle (select models only)
Sparkling water with long lasting fizz

DeepSparkle (select models only)
Sparkling water with long lasting fizz

Gaz réfrigérant

Utilise le gaz éco-réfrigérant R290.

Utilise le gaz éco-réfrigérant R290.

Operational controls

Lever controls for each dispense option.

Lever controls for each dispense option.

Dispense height

300mm

11.8"

Dimensions

C2 Tap
W165 x D220 x H510mm

C3 Tap
W235 x D235 x H510mm

Undercounter ProCore®

W320 x D430 x H375mm

C2 Tap
W6.5 x D8.7 x H20.1"

C3 Tap
W9.3 x D9.3 x H20.1"

Undercounter ProCore®
W12.6 x D16.9 x H14.8"

Alimentation électrique

230-240V~ AC (50Hz)

110-120V~ CA (60Hz)

Indice de fusible

10A

10A

Température Fraîche et Pétillante

À partir de 2°C

À partir de 2°C

Capacité Réfrigérée et Pétillante

80L

21 gal US/h

Maximum running power consumption

Chilled and ambient
0.2kW-230V

Chilled and sparkling
0.3kW-230V

Chilled, sparkling and ambient
0.3kW-230V

Chilled and ambient
0.18kW-110V

Chilled and sparkling
0.24kW-110v

Chilled, sparkling and ambient
0.24kW-110v

Rated current

Chilled and ambient
1.5A

Chilled and sparkling
1.7A

Chilled, sparkling and ambient
1.7A

Chilled and ambient
2A

Chilled and sparkling
2.6A

Chilled, sparkling and ambient
2.6A

Gaz de réfrigération

R290 40g

R290 37g

Weight

Max
27kg

Max
53lb

Water inlet connection

8mm Push Fit

8mm Push Fit

Température de l'eau d'entrée

Jusqu'à 25°C

Jusqu'à 25°C

Inlet water pressure

Min
0.05MPa (0.5 bar)

Max
1.0 MPa (10 bar)

Min
7.3psi (0.05MPa)

Max
145psi (1.0 MPa)

Outlet water pressure

Internally regulated to 0.3 MPa (3 bar)

Internally regulated to 0.3 MPa (3 bar)

Connexion CO2

Raccord à emboîtement 1/4”

Raccord à emboîtement 1/4”

Pression CO2

Max
0,4MPa (4 Bar)

Max
58 psi (0,4 MPa)

Room operating temperature

Min
5°C

Max
32°C

Min
5°C

Max
32°C

Classe climatique

N

N

Niveau sonore d'émission

Max
70 dB(A)

Max
70 dB(A)

Pre-installation information

Prior to installing a C2/C3 tap and ProCore undercounter unit, ensure the following requirements are met:

  • Minimum cupboard size of 500mm x 500mm x 500mm
  • Circular tap cut out of 35mm (C2) or 50mm (C3).
  • Drip tray cut-out of 405 x 225mm. (optional) View cutting templates
  • Minimum clearance of 550mm.
  • Vent kit cut-out of 300 x 30mm (allow clearance of 45mm each side). View cutting templates
  • Worktop thickness of 20 to 70mm.
  • 10A power supply within 1.8m of the unit.
  • Mains supply potable water within 2m of the unit.
  • Mains waste kit (included) or Bluetooth waste kit (optional).

Diagram showing minimum installation requirements.

Cutting templates

Chaque système de robinet est livré avec un ensemble de gabarits de découpe pour faciliter l'installation. Si vous souhaitez découper votre plan de travail ou votre meuble bas avant la livraison de votre système de robinet, vous pouvez commander un gabarit de découpe à l'avance.

Nos gabarits de découpe imprimés sont à taille réelle pour garantir une découpe précise. Nous déclinons toute responsabilité concernant les dimensions d’un PDF téléchargé et imprimé par un tiers.

Instructions et gabarit de découpe pour la ventilation ProCore Simple Fit
Modèle de découpe pour base de ventilation ProCore® Simple-fit

Nous vous recommandons de vérifier les dimensions du kit de ventilation ProCore Simple-fit à l'aide du gabarit de découpe avant de découper le meuble bas.

Gabarit de découpe pour grand bac récupérateur encastré C2/C3
Standard Tap & Driptray Cutting Template

We recommend you check the dimensions of the tap and driptray using the cutting template prior to cutting the work surface.

What's in the box

Kits d'installation et filtres ne sont PAS inclus et sont fournis en tant qu'articles supplémentaires selon les besoins spécifiques de commande.
Achetez maintenant

Product front

Contents:
1 x C2/C3 Tap
1 x Drip Tray
1 x Connector Cable
1 x Earth Wire
1 x Waste Drain Pipe
1 x Fixings Set
1 x Baseplate Cutting Guide
1 x ProCore Unit
1 x Power Cord Set
1 x DeepSparkle Kit (Sparkling models only)
1 x Simple-fit Ventilation Kit

Outlet number will vary dependant on model.

Product rear

Kits d'installation et filtres ne sont PAS inclus et sont fournis en tant qu'articles supplémentaires selon les besoins spécifiques de commande.
Achetez maintenant

Dimensions

How-to-install video

Installation

The Borg & Overström Simple-fit Vent Kit must be used during installation. Failure to do so will invalidate the warranty for that unit.
Shop Ventilation Kits

Un bloc d'eau doit être installé avec chaque unité. Le non-respect de cette consigne annulera la garantie de cette unité. Ceux-ci sont inclus dans nos kits d'installation.
Acheter des blocs d'eau

Installation requirements

230V

115V

Water

Mains potable water
Inlet water pressure from 0.05MPa (0.5 bar) - 1.0 MPa (10 bar)

Mains potable water
Inlet water pressure from 7.3psi (0.05MPa) - 145psi (1.0MPa)

Room operating temperature

Min
5°C

Max
32°C

Min
5°C

Max
32°C

CO₂

CO₂ de qualité alimentaire à fournir

CO₂ de qualité alimentaire à fournir

Électricité

Alimentation 10A - Protection contre les fuites à la terre

Alimentation 10A - Protection contre les fuites à la terre (Pour les États-Unis et le Canada, l'alimentation doit être protégée par un disjoncteur différentiel à haute sensibilité (GFCI))

Déchets

Raccordement de vidange principale ou kit de déchets Bluetooth

Raccordement de vidange principale ou kit de déchets Bluetooth

Identify a suitable location for the ProCore® undercounter unit. It should be positioned within 1.0m of the tap, and within 2.0m of suitable services connections. Ensure to allow enough space for the Simple-fit Vent Kit which must be installed with the unit. See Pre-Installation guide here for full installation requirements before proceeding with installation.

We recommend using an installation kit, which includes everything needed to complete the installation.

You will need:

  • Installation kit, including water block and filter. Your kit will depend on your requirements and model. See installation kit guide here.
  • Water block
  • Installation Kit
  • Jigsaw
  • Hole saw
  • Cordless drill
  • John Guest pipe cutters
  • Adjustable spanner
  • Side cutters
  • Screwdriver
  • Allen key set
  • 1L measuring jug

C2 or C3 tap system?

The first step of your installation will depend on your tap system. If you have a C2 tap system, begin with Section 1a. If you have a C3 tap system, proceed directly to Section 1b.

C2 tap system

To start the installation of a C2 tap system, follow Section 1a.

C3 tap system

To start the installation of a C3 tap system, proceed directly to Section 1b.

Section 1a - Installing a C2 countertop tap system

1

The following section applies to C2 tap installation only. If you are installing a C3 tap, skip to Section 1b. This operation must only be carried out by trained staff.

2

Identify a suitable location for the tap. Ensure worktop is level to allow system to drain and that there are no obstructions below.

3

Ensure there is adequate cupboard space beneath the faucet location (500 × 500 mm) to install the ProCore unit. Allow clear access to service isolator fixings for both water and power, and leave sufficient space for the water filter, and CO₂ canister on sparkling models.

4

Allow 550mm for the height of the tap under any overhanging cupboard/shelf.

5

Place a piece of masking tape onto the edge of the worktop and mark the centre of the drip tray.

6

Position the cutting template provided the desired distance away from the edge of the work surface, and secure in place. Make sure the centre lines up with your mark on the masking tape.

7

Drill the four corner holes of the drip tray with a 10mm drill bit.

8

Drill a pilot hole for the tap using a 4mm drill bit.

9

Remove the template and clear any sawdust.

10

Using masking tape and a straight edge, mark out the guidelines between the four holes of the drip tray.

11

Using a jigsaw carefully cut out along the lines and remove the waste piece of work surface.

12

Use a 35 mm hole saw to drill the tap access hole.

13

Clean any sawdust and make sure the surface is left clean and dry.

14

Apply a thin bead of clear silicone to the underside edge of the drip tray.

15

Position the drip tray squarely into the cut out. Apply pressure, to ensure it is well bonded and clean away any excess silicone.

16

Place the waste spigot through the waste hole in the drip tray. Thread the nut onto the waste spigot underneath the driptray.

17

Depending on your waste option, either fit the waste cap or attach the waste pipe, connecting to the drain or Bluetooth alarmed waste kit.

18

Position the tap into the tap cut-out.

19

Tighten the back nut onto the tap thread underneath the countertop. Do not overtighten.

20

Thread each individual tap head onto the tap column. Take note of the order of the dispensing options.

Section 1b - Installing a C3 countertop tap system

1

The following section applies to C3 tap installation only. If you are installing a C2 tap, complete Section 1a and proceed to Section 2.
This operation must only be carried out by trained staff.

2

Identify a suitable location for the tap. Ensure worktop is level to allow system to drain and that there are no obstructions below.

3

Ensure there is adequate cupboard space beneath the faucet location (500 × 500 mm) to install the ProCore unit. Allow clear access to service isolator fixings for both water and power, and leave sufficient space for the water filter, and CO₂ canister on sparkling models.

4

Allow 550mm for the height of the tap under any overhanging cupboard/shelf.

5

Place a piece of masking tape onto the edge of the worktop and mark the centre of the drip tray.

6

Position the cutting template provided the desired distance away from the edge of the work surface, and secure in place. Make sure the centre lines up with your mark on the masking tape.

7

Drill the four corner holes of the drip tray with a 10mm drill bit.

8

Drill a pilot hole for the tap using a 4mm drill bit.

9

Remove the template and clear any sawdust.

10

Using masking tape and a straight edge, mark out the guidelines between the four holes of the drip tray.

11

Using a jigsaw carefully cut out along the lines and remove the waste piece of work surface.

12

Use a 50 mm hole saw to drill the tap access hole.

13

Clean any sawdust and make sure the surface is left clean and dry.

14

Apply a thin bead of clear silicone to the underside edge of the drip tray.

15

Position the drip tray squarely into the cut out. Apply pressure, to ensure it is well bonded and clean away any excess silicone.

16

Place the waste spigot through the waste hole in the drip tray. Thread the nut onto the waste spigot underneath the driptray.

17

Depending on your waste option, either fit the waste cap or attach the waste pipe, connecting to the drain or Bluetooth alarmed waste kit.

18

Position the tap into the tap cut-out.

19

Tighten the back nut onto the tap thread underneath the countertop. Do not overtighten.

20

Thread each individual tap head onto the tap column. Take note of the order of the dispensing options.

Section 2 - Installing the undercounter ProCore and Simple-Fit vent kit

Avant de faire des découpes dans le placard ou la plinthe, assurez-vous que la zone à découper est exempte de tuyaux d'eau ou de câbles électriques. Il y a un risque de blessure grave ou de décès si des câbles électriques sont coupés, et des dommages importants aux biens si un tuyau d'eau est sectionné.

1

This operation must only be carried out by trained staff.

2

Décidez où vous souhaitez placer le ProCore, au centre ou sur un côté du placard. Vous aurez besoin de suffisamment d'espace pour une cartouche de CO₂ (modèles pétillants uniquement) et un filtre à eau. Assurez-vous de laisser un espace d'au moins 45 mm de chaque côté du ProCore®.

3

En utilisant le gabarit de découpe fourni, pliez le long de la ligne latérale appropriée, puis pliez le long du bord avant et fixez avec du ruban adhésif.

4

Prenez une mèche à bois de dix millimètres et percez les deux trous de guidage indiqués sur le gabarit.

5

Supprimez le modèle.

6

Appliquez du ruban adhésif de masquage pour protéger et tracez des lignes prêtes à être découpées.

7

Utilisez une scie sauteuse pour découper soigneusement le long des lignes en prenant soin de ne pas endommager le socle.

8

Retirez le ruban adhésif de masquage et enlevez la sciure.

9

Placez la base de ventilation Simple-fit au centre de l'ouverture. Assurez-vous qu'il y ait un espace d'air d'au moins 30 mm de chaque côté.

10

Line up the vent flue chimney with the backplate. Then place over the slots and slide downwards into place.

11

Lower the ProCore® carefully into position on the ventilation base to ensure the rear vent duct is located correctly in Simple Fit vent Flue at the rear of the base.

12

Assurez-vous que les évents ne sont pas obstrués. Toute obstruction affectera négativement le flux d'air vers l'appareil, ce qui pourrait entraîner une mauvaise performance, une surchauffe ou une panne du réfrigérateur.

Section 3 - Connecting the tap to the ProCore

1

Installez le bloc d'eau. Ne pas le faire annulera la garantie de cette unité.

2

Install the installation kit into the cupboard. Leave room for the filters to be changes when required.

3

Connect the filter to the mains water supply. Use locking clips on each connection for security.

4

Using the measuring jug, turn on the water supply and flush the filters to waste until it runs clear.

5

Using the 8mm push-fit fitting, connect the filter to the unit.

6

Using the black water pipes, slide on the provided black insulation and connect each pipe between the corresponding water outlet and C2 metal spigot.

7

Si vous avez un modèle pétillant, connectez l'alimentation en CO2 depuis le régulateur de gaz et suivez la section d'installation du CO2 ci-dessous.

8

Connect the unit to the electricity supply and switch on.

9

Sparkling models should have the carbonator purged of air by activating the sparkling water dispense for approximately 10 seconds.

10

Ouvrez l'alimentation en eau.

11

Allow the machine to stand for 10 minutes for the initial chilling process to complete.

12

Flush water through each dispense option. Ensure everything functions correctly and is clean.

13

We recommend that the unit undergoes a sanitisation procedure. You can follow the instructions below. Your unit is now ready for use.

CO2 bottle installation - Sparkling models only

1

Cette opération doit être effectuée uniquement par du personnel formé.

2

Déballez le régulateur de CO2 et fixez le raccord coudé à la sortie du robinet.

3

Make sure the regulator is off by twisting the top knob anti-clockwise before attaching to the CO2 bottle. Do not overtwist.

4

Fixez le régulateur à la bouteille de CO2 jetable, en veillant à ce que la petite soupape de décharge de pression sur la tige soit orientée à l'opposé de vous et des autres. Serrez à la main de manière sécurisée.

5

Connect the assembled CO2 bottle and regulator to the CO2 inlet using a ¼” pipe. Add a locking clip at either end to secure in place.

6

Stand the cylinder upright in a suitable location.

7

Réglez la pression de CO₂ sur le manomètre en tournant manuellement le bouton supérieur jusqu'à ce que le manomètre indique 3,5 - 4 bars (58 PSI). Ne dépassez pas une pression de 4 bars.

How to use

Tap control panel

Outlet number will vary dependant on model.

How to dispense water

  • To dispense water, pull and hold the desired water dispense lever. Release to finish dispensing.

Maintenance & cleaning

Sanitisation guide

Le produit est livré de l'usine en état propre, mais nous recommandons d'effectuer une procédure de désinfection lors de l'installation, conformément aux instructions de désinfection ci-dessous. Nous recommandons de répéter la désinfection tous les 6 mois.

Le non-respect de l'utilisation des matériaux et des procédés de désinfection approuvés et/ou recommandés par Borg & Overström pourrait annuler votre garantie.
Contactez-nous pour plus d'informations

You will need

  • Measuring jug
  • Protective gloves
  • Hydrogen Peroxide (H202 3%) food safe sanitising solution
  • Service filter cartridge
  • Sanitising wipes
  • Water filter

1

Cette opération doit être effectuée uniquement par du personnel formé.

2

Une procédure de désinfection est recommandée tous les 6 mois.

3

Coupez l'arrivée d'eau principale.

4

Appuyez brièvement sur le bouton de distribution d'eau froide pour libérer la pression interne de l'eau dans la machine.

5

Retirez le filtre existant.

6

Utilisez du gel pour les mains et mettez des gants de protection.

7

Ajoutez 25 ml (environ 1 fl oz US) de solution désinfectante de peroxyde d'hydrogène (H2O2 3 %) dans une cartouche de filtre de service propre et vide.

8

Connectez-vous à la tête de filtre.

9

Ouvrez l'arrivée d'eau et laissez la cartouche du filtre de service se remplir.

10

Distribuez de l'eau en utilisant le bouton d'eau froide. Répétez avec les boutons d'eau pétillante et d'eau ambiante.

11

Laissez la solution à l'intérieur de la machine pour que la désinfection prenne effet (minimum 5 minutes) tout en nettoyant soigneusement le distributeur à l'extérieur.

12

Faites particulièrement attention au robinet de distribution et aux boutons-poussoirs. Pour cela, utilisez un désinfectant externe et des lingettes désinfectantes. 

13

Nettoyez le bac d'égouttement. Si un système de débordement des déchets est installé, videz-le et rincez-le avec une petite quantité de liquide désinfectant si nécessaire.

14

Essuyez les marques cosmétiques si nécessaire. Pour cela, nous recommandons d'utiliser de l'eau tiède savonneuse.

15

Reconnectez l'alimentation et allumez le distributeur.

16

Une fois le nettoyage externe terminé, faites passer 10 L (environ 4 1/4 pintes US) d'eau à travers chaque option de distribution (Froid, Pétillant, Ambiant).

17

Coupez l'eau et appuyez brièvement sur le bouton de distribution d'eau froide pour libérer la pression interne de l'eau dans la machine.

18

Supprimez le filtre de service. Conservez le filtre de service pour une réutilisation.

19

Installez un nouveau filtre et ouvrez l'arrivée d'eau.

Sanitisation guide 20
20

Rincez d'abord le nouveau filtre à l'eau usée en utilisant le bouton refroidi jusqu'à ce que 5 L (environ 2 pintes US) d'eau aient été évacués. Répétez cette opération pour toutes les options de distribution. Votre distributeur est maintenant prêt à être utilisé.

Care and maintenance of tap finish

The finishes are typically low-maintenance and retain their look with minimal effort. However regular cleaning and maintenance will ensure longevity and aesthetic appearance.

For best results polish the dispenser with a soft cloth as necessary, as soon as signs of dirt or smudging appear. Weekly cleaning with damp cloth using mild soap and water is recommended to maintain shine and remove fingerprints. Dry and polish with a soft cloth.

WARNING: Improper use of cleaners and sterilizers or exposure to strong chemicals can cause corrosion, staining and discolouration. Avoid abrasive or harsh cleaning agents that can damage the finish.

Please note that surface contamination and the surrounding environment can accelerate staining and discolouration e.g. marine environments where salt is present or places with high humidity.

Advanced setup

Certain features can be adjusted by a trained installer as part of the product set up.

Adjusting dispense flow rate

1

Each dispense option has a flow controller to the right of the dispense lever. To increase the dispense flow rate, turn the flow controller anti-clockwise.

2

To reduce the water flow rate, turn the flow controller clockwise.

Advanced troubleshooting

Troubleshooting

Défaut/Problème

Cause possible

Action suggérée

No water dispensing

Water pressure regulator

Check water flow through the regulator. Replace if necessary.

Eau isolée de l'unité

Vérifiez que l'arrivée d'eau est ouverte.

Pas d'eau pétillante

Pas de pression CO2

Vérifiez la bouteille de CO2, le régulateur et la valve anti-retour. La pression d'alimentation doit être de 58 psi (4 bar), remplacez-les si nécessaire.

Le réservoir du carbonateur ne se remplit pas

Vérifiez la sonde du carbonateur pour un éventuel court-circuit à la terre.
Vérifiez le délai d'attente de la pompe, coupez puis remettez l'alimentation, puis purgez le carbonateur.

Carbonatation de mauvaise qualité

Pression de CO2 incorrecte

Vérifiez la bouteille de CO2, le régulateur et la valve anti-retour. La pression d'alimentation doit être de 58 psi (4 bar), remplacez-les si nécessaire.

Air dans le réservoir du carbonateur

Purger le réservoir du carbonateur. Suivez les instructions ci-dessous.

Résidu dans le réservoir du carbonateur

Après une utilisation prolongée, un film de surface peut se former à l'intérieur du réservoir du carbonateur. Reportez-vous aux instructions de nettoyage et de désinfection.

Boissons non réfrigérées

Flux d'air de refroidissement insuffisant autour du ProCore®

Vérifiez que le condenseur n'est pas bloqué. Vérifiez que les ventilateurs de refroidissement fonctionnent.
Assurez-vous que les exigences de ventilation ont été respectées.

Compresseur en panne

Vérifiez l'alimentation électrique du compresseur (tension secteur).
Vérifiez que la sonde NTC n'est pas défectueuse.
Vérifiez que la sonde NTC du DryBlock est connectée aux deux extrémités.
Vérifiez une surchauffe du système. Laissez l'appareil refroidir et vérifiez les obstructions du flux d'air. Une fois l'appareil refroidi, le système de refroidissement redémarrera. Si le problème persiste, contactez le support technique.

Panne du refroidisseur

Si le compresseur et le ventilateur fonctionnent mais qu'il n'y a pas de refroidissement, contactez le support technique.

Eau stagnante au fond de la machine

Raccord d'eau à ajustement lâche

Contactez votre distributeur.

Sonde de niveau de carbonatation déconnectée

Assurez-vous de connecter le faisceau de câblage du niveau du carburateur à la sonde de niveau du réservoir de carbonatation.

Mauvais écoulement laminaire ou éclaboussures à la sortie

Dépôt de calcaire obstruant la sortie

Remplacer l'ensemble de la prise.

Warning audio sequences

In the event of the ProCore Unit emitting an audio warning please see the sequences below for diagnostics.

Surchauffe interne déclenchée
Surchauffe due à une installation incorrecte de la ventilation.

Temps d'arrêt maximal du compresseur
Le compresseur ne peut pas atteindre la température de consigne.
Manque de gaz de réfrigération, fuite,
surutilisation, température de l'eau d'entrée trop élevée.

Emptying sparkling water

1

Coupez l'alimentation en eau.

2

Pull and hold the sparkling water dispense lever until all the water is expelled and only CO2 gas is being released.

3

The tank is empty of sparkling water when only CO2 is being released and no water is emitted.

4

Ensure to release the Sparkling water lever and take care to avoid releasing excess amounts of CO2 gas as this may damage the tank.

Technical information

C2 Chilled & Ambient circuit schematic

C2 Chilled & Sparkling circuit schematic

C3 Chilled, Sparkling & Ambient circuit schematic

C2 Chilled & Ambient water pathway

C2 Chilled & Sparkling water pathway

C3 Chilled, Sparkling & Ambient water pathway

Spares

ProCore exploded parts diagram

C2/C3 exploded parts diagram

Safety critical spares

Part no.
Description
CA
CS
CSA
701819
Levier de robinet G5/8 x 35 x 10 avec compensateur - Sortie et poignée en acier inoxydable chromé
720337
Assemblage de la carte de commande principale PCBA
462667
Clapet anti-retour simple 5/16" (8 mm) PF
462668
Clapet anti-retour simple 1/4" à emboîtement
462872
Connecteur droit égal 8 mm - Paquet de 10
702770
Pompe de surpression à membrane - Pompe à eau pétillante à faible débit 230 V
702558
Ventilateur de refroidissement 24 V avec métier à tisser
702078
Interrupteur de débit FS-16
702878
Faisceau de capteurs tout-en-un avec connecteurs KK
720023
Sonde de température

Cosmetic spares

Part no.
Description
CA
CS
CSA
604033
Poignée de robinet C2/C3 - Chromée, lot de 5
700721
Panneau supérieur (VMI)
720117
Panneau latéral droit du ProCore
720113
Panneau latéral gauche du ProCore
720045
Assemblage de porte ProCore complet
609124
Ensemble d'étiquettes pour dôme de robinet C2/C3

Contact support for any required spares not listed above.

Tous les composants doivent être remplacés par un technicien agréé par l'usine avec des composants approuvés par le fabricant (listés ci-dessus), afin de minimiser les risques pour la santé et la sécurité liés aux dangers électriques et au risque d'incendie dus à des pièces incorrectes ou à un service inapproprié.

Borg & Overström