Sécurité
Specification
Product specifications
Pre-installation information
Diagram showing minimum installation requirements.
Cutting templates
What's in the box
Product front
Contents:
1 x T3 Tap
1 x Baseplate (Standard or MonoFit)
1 x Drip Tray
1 x 1.0m x 6mm Insulated Water Pipe
1 x Connector Cable
1 x Earth Wire
1 x Waste Drain Pipe
1 x Fixings Set
1 x Baseplate Cutting Guide
1 x ProCore+ Unit
1 x Power Cord Set
1 x DeepSparkle Kit (Sparkling models only)
1 x Simple-fit Ventilation Kit
Product rear
Dimensions
How-to-install video
Installation
Installation requirements
Identify a suitable location for the ProCore® undercounter unit. It should be positioned within 1.0m of the tap, and within 2.0m of suitable services connections. Ensure to allow enough space for the Simple-fit Vent Kit which must be installed with the unit. See Pre-Installation guide here for full installation requirements before proceeding with installation.
We recommend using an installation kit, which includes everything needed to complete the installation.
You will need:
- Installation kit, including water block and filter. Your kit will depend on your requirements and model. See installation kit guide here.
- Water block
- Installation Kit
- Jigsaw
- Hole saw (MonoFit® models only)
- Cordless drill
- John Guest pipe cutters
- Adjustable spanner
- Side cutters
- Screwdriver
- Allen key set
- 1L measuring jug
Standard or MonoFit?
The first step of your installation will depend on your tap system. If you have a Standard tap system, begin with Section 1a. If you have a MonoFit tap system, proceed directly to Section 1b.
To start the installation of a standard T3 tap system, follow section 1a.
To start the installation of a MonoFit tap system, proceed directly to section 1b.
Section 1a - Installing a Standard countertop tap system
Section 1b - Installing a MonoFit tap system
Position the cutting template the desired distance away from the edge of the work surface.
Place two pieces of masking tape either side of the bottom line (labelled 1B) on the cutting template. Using a straight edge, mark along line 1B continuing onto both pieces of masking tape.
Secure the cutting template into place.
Drill the access hole for the drip tray, using a 60mm circular drill bit.
Remove the cutting template, leaving the two pieces of masking tape either side of the drip tray. Clean away any sawdust.
Position the drip tray into the cutout, ensuring the front edge is parallel with the marked pieces of masking tape. Add additional sealant, if required, to ensure a watertight seal.
Section 2 - Installing the undercounter ProCore and Simple-Fit vent kit
This operation must only be carried out by trained staff.
Section 3 - Connecting the tap to the ProCore and commissioning the unit
*Expect dripping on hot dispense until the tank has reached temperature and initial dispense made. This will only occur on first heating cycle on initial start-up.
CO2 bottle installation - Sparkling models only
Make sure the regulator is off by twisting the top knob anti-clockwise before attaching to the CO2 bottle. Do not overtwist.
How to use
Tap control panel
Illuminated indicators
How to dispense water
Maintenance & cleaning
Sanitisation guide
You will need
- Measuring jug
- Protective gloves
- Hydrogen Peroxide (H202 3%) food safe sanitising solution
- Service filter cartridge
- Sanitising wipes
- Water filter
Care and maintenance of tap finish
Advanced troubleshooting
Advanced functions
Troubleshooting
Warning flash sequences
In the event of the warning triangle flashing please see the sequences below for diagnostics.
Advanced setup
Emptying sparkling water
Draining the hot tank
If you are decommissioning a unit, or descaling the hot tank you must first drain the hot tank.
To do so proceed with the following steps:
Ensure the unit is put back into commissioning mode before proceeding. Start by turning the unit off and on again.
Place the front and top panel back on to the unit by sliding them into place and replacing the screws.
Adjusting sparkling water flow rate
NOTE: Sparkling water flow rate factory setting = 1.8L (0.4 Gal) per minute MAX. This may need adjusting depending on inlet pressure. To do so follow below steps:
Sparkling models only
Technical information
T3 Chilled, Ambient & Hot circuit schematic
T3 Chilled, Ambient, Sparkling & Hot circuit schematic
T3 Chilled, Ambient & Hot water pathway
T3 Chilled, Ambient, Sparkling & Hot water pathway
Spares
ProCore exploded parts diagram
T3 exploded parts diagram
Safety critical spares
Interrupteur de débit CNKB FS-7
Assemblage de la carte de commande principale PCBA
Pompe de surpression à membrane - Pompe à eau pétillante à faible débit 115 V
Pompe de surpression à membrane - Pompe à eau pétillante à faible débit 230 V
Ventilateur de refroidissement 24 V avec métier à tisser
Réservoir d'eau chaude 800 W avec vase d'expansion 115 V
Ballon d'eau chaude de 1,5 kW avec vase d'expansion 230 V
Kit de pièces de rechange pour assemblage UV
Solénoïde 3/4” BSP 8 mm PF
Clapet anti-retour simple 5/16" (8 mm) PF
Électrovanne de distribution 3:1 8 mm
Électrovanne de distribution 2:1 8 mm
Vanne de régulation du débit d'eau pétillante
Faisceau de capteurs tout-en-un avec connecteurs KK
Métier à tisser solénoïde du Congrès
Cosmetic spares
Panneau supérieur sous le comptoir (VMI)
Panneau latéral droit du ProCore
Panneau latéral gauche du ProCore
Assemblage de porte ProCore complet
T3 Tap Outlet 2.0 Steel - Retrofit Kit
721030
T3 Tap Outlet 2.0 Black - Retrofit Kit
721035
Grille de bac d'égouttage série T et E7 - Acier poli