Zum Inhalt springen

C2/C3 Install & Operation Manual

Handbuch teilen Geh zurück
Veröffentlichungsdatum: 25.01.2025

Sicherheit

This appliance can be used by adults and children aged 8 and above, as well as people with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, as long as they have been given instruction or supervision concerning the use of the appliance in a safe way and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be conducted by children.

The appliance shall only be maintained and repaired by authorized technicians who are properly trained and certified. The appliance should be isolated from the electricity supply before removal of any covers. Great care must be employed when working with high pressure carbon dioxide, and in no cases should the maximum operating pressure of 0.4MPa (4 bar) be exceeded.

  • The appliance must be placed upright on a flat horizontal surface.
  • The appliance must be kept away from sunlight, heat and moisture.
  • The appliance shall not be placed in lobbies or locations of egress or where it may obstruct exit access.
  • The appliance must be installed in an environment free of dust and corrosive/explosive gases.
  • The appliance is not suitable for installation in an area where a water jet could be used.
  • The appliance must not be installed where it is liable to freeze. If the unit is thought to be frozen it must not be switched on.
  • The appliance must maintain adequate mechanical stability when in use, during transportation, assembly, dismantling, scrapping and any other action.
  • The appliance must not be installed without a waterblock. Installing without a waterblock will invalidate warranty.
  • The appliance must have adequate ventilation. Installing the unit without the Simple-fit Vent Kit will invalidate the warranty.

WARNING: Keep ventilation openings in the appliance enclosure or in the built-in structure clear of obstruction.
WARNING: When positioning the appliance, ensure the supply cord is not trapped or damaged.
WARNING: Do not locate multiple portable socket-outlets or portable power supplies at the rear of the appliance.
WARNING: Increased risk of a leak could occur through improper handling, movement or use.

The appliance must be installed in accordance with the relevant requirements of:

  • The appropriate building regulations by application of either The Building Regulations (England and Wales), The Building Regulations (Scotland) or The Building Regulations (Northern Ireland). In territories other than those listed the local regulations in force must be complied with.
  • The Water Supply (Water Fittings) Regulations (England, Wales and Northern Ireland) or The Water Byelaws in Scotland.

This appliance is designed for dispensing drinking water in commercial and workplace environments, including:

  • Offices and corporate workplaces
  • Factories and industrial staff welfare areas
  • Hotels, hostels, and other hospitality environments
  • Public buildings such as schools, hospitals, and leisure facilities
  • Household environments and similar applications.

The appliance is suitable for providing chilled potable drinking water for employees, visitors, and guests.

The appliance is intended for indoor use only and must be installed and operated in accordance with the instructions provided in this manual.

Restrictions on Use
  • This appliance is not intended for heavy industrial use or continuous high-demand applications beyond its specified capacity.
  • It must only be used for dispensing potable (drinkable) water.
  • Do not use the appliance for any purpose other than that for which it is intended.
Sicherheitsmeldung zu R290

R290 ist ein Kältemittel-Propangas in Reinheitsqualität, das in einer Vielzahl von gewerblichen Kühl- und Klimaanlagen verwendet wird. Als hochreines Propan hat es eine geringe Umweltbelastung und ein nominales Treibhauspotenzial (GWP), was bedeutet, dass es keine Eigenschaften besitzt, die die Ozonschicht zerstören können. R290 ist außerdem die bevorzugte Kohlenwasserstoff-Alternative der Umweltbehörde (EPA) und ersetzt schädlichere Fluorkohlenwasserstoff-Kältemittel wie R22, R134a, R404a und R502. Anlagen mit R290 dürfen nur von autorisierten Technikern gewartet und repariert werden, die entsprechend geschult und zertifiziert sind.

Elektrische Abfallprodukte

Als Hersteller gemäß den britischen WEEE-Vorschriften erfüllt Borg and Overström seine Herstellerpflichten, indem es als Mitglied eines WEEE-Konformitätsprogramms registriert ist und eine WEEE-Herstellernummer besitzt. Dieses Produkt ist aus Materialien gefertigt, die recycelt und wiederverwendet werden können. Das Symbol bedeutet, dass das Produkt am Ende seiner Lebensdauer getrennt vom Hausmüll entsorgt werden sollte.
Hersteller-WEEE-Registrierungsnummer: WEE/KG0136ZT

Specification

Product specifications

230V

115V

Water options

Chilled, Sparkling and Ambient
*Your water options will vary depending on your model.

Chilled, Sparkling and Ambient
*Your water options will vary depending on your model.

System

DryChill® Kühlsystem
Hygienische Schnellkühltechnologie. Solider Aluminiumkern mit hygienischer Kühlmittelschlange aus Edelstahl. Verwendet das umweltfreundliche Kältemittel R290.

DryChill® Kühlsystem
Hygienische Schnellkühltechnologie. Solider Aluminiumkern mit hygienischer Edelstahl-Kühlmittelschlange. Verwendet umweltfreundliches Kältemittel R290 Gas.

Hygiene

Gesamtheit
5-Schritte-Hygienemethode

Viovandt (nur ausgewählte Modelle)
Eco LED UV-C-Technologie

Gesamtheit
5-Schritte-Hygienemethode

Viovandt (nur ausgewählte Modelle)
Eco LED UV-C-Technologie

Technology

DeepSparkle (select models only)
Sparkling water with long lasting fizz

DeepSparkle (select models only)
Sparkling water with long lasting fizz

Kältemittelgas

Verwendet umweltfreundliches Kältemittel R290.

Verwendet umweltfreundliches Kältemittel R290.

Operational controls

Lever controls for each dispense option.

Lever controls for each dispense option.

Dispense height

300mm

11.8"

Dimensions

C2 Tap
W165 x D220 x H510mm

C3 Tap
W235 x D235 x H510mm

Undercounter ProCore®

W320 x D430 x H375mm

C2 Tap
W6.5 x D8.7 x H20.1"

C3 Tap
W9.3 x D9.3 x H20.1"

Undercounter ProCore®
W12.6 x D16.9 x H14.8"

Stromversorgung

230-240V~ Wechselstrom (50Hz)

110-120V~ Wechselstrom (60Hz)

Sicherungsauswertung

10A

10A

Gekühlte & sprudlnde Temperatur

Ab 2°C

Ab 2 °C

Gekühlte & sprudlnde Kapazität

80L

21 US-Gal/h

Maximum running power consumption

Chilled and ambient
0.2kW-230V

Chilled and sparkling
0.3kW-230V

Chilled, sparkling and ambient
0.3kW-230V

Chilled and ambient
0.18kW-110V

Chilled and sparkling
0.24kW-110v

Chilled, sparkling and ambient
0.24kW-110v

Rated current

Chilled and ambient
1.5A

Chilled and sparkling
1.7A

Chilled, sparkling and ambient
1.7A

Chilled and ambient
2A

Chilled and sparkling
2.6A

Chilled, sparkling and ambient
2.6A

Kühlgas

R290 40g

R290 37g

Weight

Max
27kg

Max
53lb

Water inlet connection

8mm Push Fit

8mm Push Fit

Einlasstemperatur des Wassers

Bis zu 25°C

Bis zu 77°F

Inlet water pressure

Min
0.05MPa (0.5 bar)

Max
1.0 MPa (10 bar)

Min
7.3psi (0.05MPa)

Max
145psi (1.0 MPa)

Outlet water pressure

Internally regulated to 0.3 MPa (3 bar)

Internally regulated to 0.3 MPa (3 bar)

CO2-Verbindung

1/4” Steckanschluss

1/4” Steckanschluss

CO2-Druck

Maximal
0,4 MPa (4 Bar)

Max
58 psi (0,4 MPa)

Room operating temperature

Min
5°C

Max
32°C

Min
5°C

Max
32°C

Klimaklasse

N

N

Emissionsgeräuschpegel

Maximal
70 dB(A)

Maximal
70 dB(A)

Pre-installation information

Prior to installing a C2/C3 tap and ProCore undercounter unit, ensure the following requirements are met:

  • Minimum cupboard size of 500mm x 500mm x 500mm
  • Circular tap cut out of 35mm (C2) or 50mm (C3).
  • Drip tray cut-out of 405 x 225mm. (optional) View cutting templates
  • Minimum clearance of 550mm.
  • Vent kit cut-out of 300 x 30mm (allow clearance of 45mm each side). View cutting templates
  • Worktop thickness of 20 to 70mm.
  • 10A power supply within 1.8m of the unit.
  • Mains supply potable water within 2m of the unit.
  • Mains waste kit (included) or Bluetooth waste kit (optional).

Diagram showing minimum installation requirements.

Cutting templates

Jedes Zapfsystem wird mit einem Satz Schneidvorlagen zur einfachen Installation geliefert. Wenn Sie Ihre Arbeitsplatte oder den Unterschrank vor der Lieferung Ihres Zapfsystems zuschneiden möchten, können Sie eine Schneidvorlage im Voraus bestellen.

Unsere gedruckten Schnittvorlagen sind in Originalgröße, um ein genaues Zuschneiden zu gewährleisten. Wir übernehmen keine Verantwortung für Maße einer PDF-Datei, die von einer externen Partei heruntergeladen und ausgedruckt wurde.

Anleitung und Schnittvorlage für die ProCore Simple Fit-Belüftung
ProCore® Einfach anzupassende Vorlage für die Lüftungsbasis zum Zuschneiden

Wir empfehlen Ihnen, die Maße des ProCore Simple-fit Belüftungskits mit der Schneideschablone zu überprüfen, bevor Sie den Unterschrank zuschneiden.

Schneideschablone für C2/C3 große flächenbündige Tropfschale
Standard Tap & Driptray Cutting Template

We recommend you check the dimensions of the tap and driptray using the cutting template prior to cutting the work surface.

What's in the box

Montagesätze und Filter sind NICHT enthalten und werden je nach individuellem Bestellbedarf als zusätzliche Artikel geliefert.
Jetzt einkaufen

Product front

Contents:
1 x C2/C3 Tap
1 x Drip Tray
1 x Connector Cable
1 x Earth Wire
1 x Waste Drain Pipe
1 x Fixings Set
1 x Baseplate Cutting Guide
1 x ProCore Unit
1 x Power Cord Set
1 x DeepSparkle Kit (Sparkling models only)
1 x Simple-fit Ventilation Kit

Outlet number will vary dependant on model.

Product rear

Montagesätze und Filter sind NICHT enthalten und werden je nach individuellem Bestellbedarf als zusätzliche Artikel geliefert.
Jetzt einkaufen

Dimensions

How-to-install video

Installation

The Borg & Overström Simple-fit Vent Kit must be used during installation. Failure to do so will invalidate the warranty for that unit.
Shop Ventilation Kits

Ein Wasserblock muss neben jeder Einheit installiert werden. Wird dies nicht beachtet, erlischt die Garantie für diese Einheit. Diese sind in unseren Installationskits enthalten.
Wasserblöcke kaufen

Installation requirements

230V

115V

Water

Mains potable water
Inlet water pressure from 0.05MPa (0.5 bar) - 1.0 MPa (10 bar)

Mains potable water
Inlet water pressure from 7.3psi (0.05MPa) - 145psi (1.0MPa)

Room operating temperature

Min
5°C

Max
32°C

Min
5°C

Max
32°C

CO₂

Lebensmitteltaugliches CO₂ bereitzustellen

Lebensmitteltaugliches CO₂ bereitzustellen

Elektrizität

10A Versorgung - Fehlerstromschutz

10A Versorgung - Fehlerstromschutz (Für USA & Kanada muss die Versorgung durch einen Fehlerstrom-Schutzschalter (GFCI) geschützt sein)

Abfall

Hauptabflussanschluss oder Bluetooth-Abfallset

Hauptabflussanschluss oder Bluetooth-Abfallset

Identify a suitable location for the ProCore® undercounter unit. It should be positioned within 1.0m of the tap, and within 2.0m of suitable services connections. Ensure to allow enough space for the Simple-fit Vent Kit which must be installed with the unit. See Pre-Installation guide here for full installation requirements before proceeding with installation.

We recommend using an installation kit, which includes everything needed to complete the installation.

You will need:

  • Installation kit, including water block and filter. Your kit will depend on your requirements and model. See installation kit guide here.
  • Water block
  • Installation Kit
  • Jigsaw
  • Hole saw
  • Cordless drill
  • John Guest pipe cutters
  • Adjustable spanner
  • Side cutters
  • Screwdriver
  • Allen key set
  • 1L measuring jug

C2 or C3 tap system?

The first step of your installation will depend on your tap system. If you have a C2 tap system, begin with Section 1a. If you have a C3 tap system, proceed directly to Section 1b.

C2 tap system

To start the installation of a C2 tap system, follow Section 1a.

C3 tap system

To start the installation of a C3 tap system, proceed directly to Section 1b.

Section 1a - Installing a C2 countertop tap system

1

The following section applies to C2 tap installation only. If you are installing a C3 tap, skip to Section 1b. This operation must only be carried out by trained staff.

2

Identify a suitable location for the tap. Ensure worktop is level to allow system to drain and that there are no obstructions below.

3

Ensure there is adequate cupboard space beneath the faucet location (500 × 500 mm) to install the ProCore unit. Allow clear access to service isolator fixings for both water and power, and leave sufficient space for the water filter, and CO₂ canister on sparkling models.

4

Allow 550mm for the height of the tap under any overhanging cupboard/shelf.

5

Place a piece of masking tape onto the edge of the worktop and mark the centre of the drip tray.

6

Position the cutting template provided the desired distance away from the edge of the work surface, and secure in place. Make sure the centre lines up with your mark on the masking tape.

7

Drill the four corner holes of the drip tray with a 10mm drill bit.

8

Drill a pilot hole for the tap using a 4mm drill bit.

9

Remove the template and clear any sawdust.

10

Using masking tape and a straight edge, mark out the guidelines between the four holes of the drip tray.

11

Using a jigsaw carefully cut out along the lines and remove the waste piece of work surface.

12

Use a 35 mm hole saw to drill the tap access hole.

13

Clean any sawdust and make sure the surface is left clean and dry.

14

Apply a thin bead of clear silicone to the underside edge of the drip tray.

15

Position the drip tray squarely into the cut out. Apply pressure, to ensure it is well bonded and clean away any excess silicone.

16

Place the waste spigot through the waste hole in the drip tray. Thread the nut onto the waste spigot underneath the driptray.

17

Depending on your waste option, either fit the waste cap or attach the waste pipe, connecting to the drain or Bluetooth alarmed waste kit.

18

Position the tap into the tap cut-out.

19

Tighten the back nut onto the tap thread underneath the countertop. Do not overtighten.

20

Thread each individual tap head onto the tap column. Take note of the order of the dispensing options.

Section 1b - Installing a C3 countertop tap system

1

The following section applies to C3 tap installation only. If you are installing a C2 tap, complete Section 1a and proceed to Section 2.
This operation must only be carried out by trained staff.

2

Identify a suitable location for the tap. Ensure worktop is level to allow system to drain and that there are no obstructions below.

3

Ensure there is adequate cupboard space beneath the faucet location (500 × 500 mm) to install the ProCore unit. Allow clear access to service isolator fixings for both water and power, and leave sufficient space for the water filter, and CO₂ canister on sparkling models.

4

Allow 550mm for the height of the tap under any overhanging cupboard/shelf.

5

Place a piece of masking tape onto the edge of the worktop and mark the centre of the drip tray.

6

Position the cutting template provided the desired distance away from the edge of the work surface, and secure in place. Make sure the centre lines up with your mark on the masking tape.

7

Drill the four corner holes of the drip tray with a 10mm drill bit.

8

Drill a pilot hole for the tap using a 4mm drill bit.

9

Remove the template and clear any sawdust.

10

Using masking tape and a straight edge, mark out the guidelines between the four holes of the drip tray.

11

Using a jigsaw carefully cut out along the lines and remove the waste piece of work surface.

12

Use a 50 mm hole saw to drill the tap access hole.

13

Clean any sawdust and make sure the surface is left clean and dry.

14

Apply a thin bead of clear silicone to the underside edge of the drip tray.

15

Position the drip tray squarely into the cut out. Apply pressure, to ensure it is well bonded and clean away any excess silicone.

16

Place the waste spigot through the waste hole in the drip tray. Thread the nut onto the waste spigot underneath the driptray.

17

Depending on your waste option, either fit the waste cap or attach the waste pipe, connecting to the drain or Bluetooth alarmed waste kit.

18

Position the tap into the tap cut-out.

19

Tighten the back nut onto the tap thread underneath the countertop. Do not overtighten.

20

Thread each individual tap head onto the tap column. Take note of the order of the dispensing options.

Section 2 - Installing the undercounter ProCore and Simple-Fit vent kit

Bevor Sie Schnitte in den Schrank oder die Sockelleiste machen, stellen Sie sicher, dass der zu schneidende Bereich frei von Wasserleitungen oder elektrischen Kabeln ist. Es besteht die Gefahr schwerer Verletzungen oder Todesfälle, wenn elektrische Kabel durchtrennt werden, und erheblicher Sachschaden, wenn eine Wasserleitung beschädigt wird.

1

This operation must only be carried out by trained staff.

2

Entscheiden Sie, wo Sie den ProCore platzieren möchten, in der Mitte oder an einer Seite des Schranks. Sie benötigen ausreichend Platz für eine CO₂-Kartusche (nur bei Sprudelmodellen) und einen Wasserfilter. Achten Sie darauf, auf beiden Seiten des ProCore® einen Abstand von mindestens 45 mm einzuhalten.

3

Verwenden Sie die bereitgestellte Schnittvorlage, falten Sie entlang der entsprechenden Seitenlinie und falten Sie entlang der Vorderkante, dann kleben Sie sie fest.

4

Nehmen Sie einen zehn Millimeter Holzbohrer und bohren Sie die beiden auf der Schablone markierten Führungsbohrungen.

5

Vorlage entfernen.

6

Tragen Sie Malerkrepp zum Schutz auf und zeichnen Sie Linien zum Schneiden vor.

7

Verwenden Sie eine Stichsäge, um vorsichtig entlang der Linien zu schneiden, und achten Sie darauf, die Sockelleiste nicht zu beschädigen.

8

Entfernen Sie das Klebeband und beseitigen Sie den Sägespäne.

9

Setzen Sie die Simple-fit-Lüftungsbasis mittig über die Öffnung. Achten Sie darauf, dass auf jeder Seite ein Luftspalt von mindestens 30 mm vorhanden ist.

10

Line up the vent flue chimney with the backplate. Then place over the slots and slide downwards into place.

11

Lower the ProCore® carefully into position on the ventilation base to ensure the rear vent duct is located correctly in Simple Fit vent Flue at the rear of the base.

12

Stellen Sie sicher, dass die Lüftungsschlitze nicht blockiert sind. Jegliche Blockierungen beeinträchtigen den Luftstrom zum Gerät, was zu schlechter Leistung, Überhitzung oder einem Ausfall des Kühlschranks führen kann.

Section 3 - Connecting the tap to the ProCore

1

Installieren Sie den Wasserblock. Wenn Sie dies nicht tun, erlischt die Garantie für dieses Gerät.

2

Install the installation kit into the cupboard. Leave room for the filters to be changes when required.

3

Connect the filter to the mains water supply. Use locking clips on each connection for security.

4

Using the measuring jug, turn on the water supply and flush the filters to waste until it runs clear.

5

Using the 8mm push-fit fitting, connect the filter to the unit.

6

Using the black water pipes, slide on the provided black insulation and connect each pipe between the corresponding water outlet and C2 metal spigot.

7

Wenn Sie ein sprudelndes Modell haben, schließen Sie die CO2-Versorgung vom Gasregler an und folgen Sie dem untenstehenden Abschnitt zur CO2-Installation.

8

Connect the unit to the electricity supply and switch on.

9

Sparkling models should have the carbonator purged of air by activating the sparkling water dispense for approximately 10 seconds.

10

Drehen Sie die Wasserzufuhr auf.

11

Allow the machine to stand for 10 minutes for the initial chilling process to complete.

12

Flush water through each dispense option. Ensure everything functions correctly and is clean.

13

We recommend that the unit undergoes a sanitisation procedure. You can follow the instructions below. Your unit is now ready for use.

CO2 bottle installation - Sparkling models only

1

Diese Operation darf nur von geschultem Personal durchgeführt werden.

2

Packen Sie den CO2-Regler aus und montieren Sie das Winkelstück am Zapfen-Ausgang.

3

Make sure the regulator is off by twisting the top knob anti-clockwise before attaching to the CO2 bottle. Do not overtwist.

4

Befestigen Sie den Regler an der Einweg-CO2-Flasche, wobei das kleine Druckentlastungsventil im Stiel von Ihnen und anderen wegzeigt. Ziehen Sie es von Hand fest an.

5

Connect the assembled CO2 bottle and regulator to the CO2 inlet using a ¼” pipe. Add a locking clip at either end to secure in place.

6

Stand the cylinder upright in a suitable location.

7

Stellen Sie den CO₂-Druck am Manometer ein, indem Sie den oberen Knopf manuell drehen, bis das Manometer 3,5 - 4 bar (58 PSI) anzeigt. Überschreiten Sie nicht den Druck von 4 bar.

How to use

Tap control panel

Outlet number will vary dependant on model.

How to dispense water

  • To dispense water, pull and hold the desired water dispense lever. Release to finish dispensing.

Maintenance & cleaning

Sanitisation guide

Das Produkt wird ab Werk in sauberem Zustand geliefert, aber wir empfehlen, am Installationsort eine Desinfektionsprozedur gemäß der untenstehenden Desinfektionsanleitung durchzuführen. Wir empfehlen, die Desinfektion alle 6 Monate zu wiederholen.

Die Nichtverwendung von von Borg & Overström genehmigten und/oder empfohlenen Desinfektionsmaterialien und -verfahren kann Ihre Garantie ungültig machen.
Kontaktieren Sie uns für weitere Informationen

You will need

  • Measuring jug
  • Protective gloves
  • Hydrogen Peroxide (H202 3%) food safe sanitising solution
  • Service filter cartridge
  • Sanitising wipes
  • Water filter

1

Diese Operation darf nur von geschultem Personal durchgeführt werden.

2

Eine Desinfektionsprozedur wird alle 6 Monate empfohlen.

3

Hauptwasserzufuhr abstellen.

4

Drücken Sie kurz die Taste für gekühltes Wasser, um den Innendruck der Maschine zu entlasten.

5

Entfernen Sie den vorhandenen Filter.

6

Verwenden Sie Handgel und ziehen Sie Schutzhandschuhe an.

7

Fügen Sie 25 ml (ca. 1 US fl oz) Wasserstoffperoxid (H2O2 3%) Desinfektionslösung zu einer sauberen und leeren Servicefilterkartusche hinzu.

8

Mit Filterkopf verbinden.

9

Drehen Sie das Zulaufwasser auf und lassen Sie die Servicefilterkartusche sich füllen.

10

Wasser mit der Taste für gekühltes Wasser ausgeben. Vorgang mit den Tasten für Sprudel- und Raumtemperaturwasser wiederholen.

11

Lassen Sie die Lösung mindestens 5 Minuten in der Maschine, damit die Desinfektion wirkt, und reinigen Sie dabei den Spender gründlich von außen.

12

Achten Sie besonders auf den Ausgabehahn und die Druckknopfsteuerungen. Verwenden Sie dafür ein externes Desinfektionsmittel und Desinfektionstücher. 

13

Reinigen Sie die Tropfschale. Wenn ein Abfallüberlaufsystem installiert ist, leeren Sie dieses und spülen Sie es bei Bedarf mit einer kleinen Menge Desinfektionsmittel durch.

14

Wischen Sie bei Bedarf kosmetische Spuren ab. Dafür empfehlen wir die Verwendung von warmem Seifenwasser.

15

Schließen Sie die Stromversorgung wieder an und schalten Sie den Spender ein.

16

Wenn die Außenreinigung abgeschlossen ist, spülen Sie 10L (ca. 4 1/4 US-Quart) Wasser durch jede Ausgabemöglichkeit (Gekühlt, sprudlnde, Raumtemperatur).

17

Schalten Sie das Wasser ab und drücken Sie kurz die Taste für gekühltes Wasser, um den internen Wasserdruck aus der Maschine zu entlassen.

18

Entfernen Sie den Servicefilter. Servicefilter zur Wiederverwendung beibehalten.

19

Neuen Filter einsetzen und die Zufuhr des einlaufenden Wassers einschalten.

20

Spülen Sie den neuen Filter zunächst mit der Taste „Kalt“ in den Abfluss, bis etwa 5 Liter (ca. 2 US-Pints) Wasser durchgelaufen sind. Wiederholen Sie dies für alle Ausgabemöglichkeiten. Ihr Spender ist jetzt einsatzbereit.

Care and maintenance of tap finish

The finishes are typically low-maintenance and retain their look with minimal effort. However regular cleaning and maintenance will ensure longevity and aesthetic appearance.

For best results polish the dispenser with a soft cloth as necessary, as soon as signs of dirt or smudging appear. Weekly cleaning with damp cloth using mild soap and water is recommended to maintain shine and remove fingerprints. Dry and polish with a soft cloth.

WARNING: Improper use of cleaners and sterilizers or exposure to strong chemicals can cause corrosion, staining and discolouration. Avoid abrasive or harsh cleaning agents that can damage the finish.

Please note that surface contamination and the surrounding environment can accelerate staining and discolouration e.g. marine environments where salt is present or places with high humidity.

Advanced setup

Certain features can be adjusted by a trained installer as part of the product set up.

Adjusting dispense flow rate

1

Each dispense option has a flow controller to the right of the dispense lever. To increase the dispense flow rate, turn the flow controller anti-clockwise.

2

To reduce the water flow rate, turn the flow controller clockwise.

Advanced troubleshooting

Troubleshooting

Fehler/Problem

Mögliche Ursache

Vorgeschlagene Aktion

No water dispensing

Water pressure regulator

Check water flow through the regulator. Replace if necessary.

Wasser, das aus dem Gerät isoliert wurde

Überprüfen Sie, ob die Wasserzufuhr geöffnet ist.

Kein sprudlndes Wasser

Kein CO2-Druck

Überprüfen Sie die CO2-Flasche, den Druckregler und das Rückschlagventil. Der Versorgungsdruck sollte 58 psi (4 bar) betragen, bei Bedarf ersetzen.

Kohlensäurebehälter füllt sich nicht

Überprüfen Sie die Karbonator-Sonde auf einen möglichen Kurzschluss zur Erde.
Überprüfen Sie die Pumpe auf Zeitüberschreitung, schalten Sie die Stromversorgung aus und wieder ein und spülen Sie dann den Karbonator.

Schlechte Kohlensäurequalität

Falscher CO2-Druck

Überprüfen Sie die CO2-Flasche, den Druckregler und das Rückschlagventil. Der Versorgungsdruck sollte 58 psi (4 bar) betragen, bei Bedarf ersetzen.

Luft im Karbonatortank

Reinigen Sie den Karbonatortank. Befolgen Sie die Anweisungen unten.

Rückstände im Karbonisatorbehälter

Nach längerem Gebrauch kann sich im Karbonisatorbehälter ein Oberflächenfilm bilden. Beachten Sie die Reinigungs- und Desinfektionsanweisungen.

Getränke nicht gekühlt

Unzureichender Kühlungsluftstrom um den ProCore®

Überprüfen Sie, ob der Kondensator nicht blockiert ist. Stellen Sie sicher, dass die Kühlventilatoren laufen.
Stellen Sie sicher, dass die Belüftungsanforderungen erfüllt sind.

Kompressor läuft nicht

Überprüfen Sie die Stromversorgung des Kompressors (Netzspannung).
Überprüfen Sie, ob die NTC-Sonde nicht defekt ist.
Überprüfen Sie, ob der DryBlock-NTC an beiden Enden angeschlossen ist.
Überprüfen Sie auf Überhitzung des Systems. Lassen Sie das Gerät abkühlen und prüfen Sie auf Luftstrombehinderungen. Sobald das Gerät abgekühlt ist, startet das Kühlsystem neu. Wenn das Problem weiterhin besteht, wenden Sie sich an den technischen Support.

Kühlaggregatausfall

Wenn der Kompressor und der Lüfter laufen, aber keine Kühlung erfolgt, wenden Sie sich an den technischen Support.

Wasser, das sich am Boden der Maschine befindet

Locker sitzende Wasseranschlussverbindung

Kontaktieren Sie Ihren Händler.

Kohlensäuregehaltssonde getrennt

Stellen Sie sicher, dass der Kabelbaum des Vergaserniveaus mit der Niveausonde des Karbonisierungstanks verbunden ist.

Schlechter laminare Strömung oder Spritzen am Auslass

Kalkablagerungen verengen den Auslass

Baugruppe der Steckdose ersetzen.

Warning audio sequences

In the event of the ProCore Unit emitting an audio warning please see the sequences below for diagnostics.

Interne Überhitzung ausgelöst
Überhitzung aufgrund falscher Lüftungsinstallation.

Kompressor Zeitüberschreitung maximal
Kompressor kann Solltemperatur nicht erreichen. Mangel an Kältemittel, Leckage, Überbeanspruchung, Einlasswassertemperatur zu hoch.

Emptying sparkling water

1

Drehen Sie die Wasserzufuhr ab.

2

Pull and hold the sparkling water dispense lever until all the water is expelled and only CO2 gas is being released.

3

The tank is empty of sparkling water when only CO2 is being released and no water is emitted.

4

Ensure to release the Sparkling water lever and take care to avoid releasing excess amounts of CO2 gas as this may damage the tank.

Technical information

C2 Chilled & Ambient circuit schematic

C2 Chilled & Sparkling circuit schematic

C3 Chilled, Sparkling & Ambient circuit schematic

C2 Chilled & Ambient water pathway

C2 Chilled & Sparkling water pathway

C3 Chilled, Sparkling & Ambient water pathway

Spares

ProCore exploded parts diagram

C2/C3 exploded parts diagram

Safety critical spares

Part no.
Description
CA
CS
CSA
701819
Hahnhebel G5/8x35x10 mit Kompensator - SS Chrom Auslass & Griff
720337
PCBA-Hauptsteuerplatinenbaugruppe
462667
Einzelrückschlagventil 5/16" (8mm) PF
462668
Einzelnes Rückschlagventil 1/4" Steckverbindung
462872
Gleicher gerader Verbinder 8 mm – 10er-Pack
702770
Membran-Druckerhöhungspumpe – Sprudelwasserpumpe mit geringer Durchflussrate, 230 V
702558
Kühllüfter 24 V mit Kabelbaum
702078
FS-16 Durchflussschalter
702878
All-in-One-Sensorkabelbaum mit KK-Anschlüssen
720023
Temperaturfühler

Cosmetic spares

Part no.
Description
CA
CS
CSA
604033
C2/C3 Zapfhahngriff - Verchromt, 5er-Pack
700721
Oberes Bedienfeld (VMI)
720117
ProCore Rechte Seitenwand
720113
ProCore Linke Seitenwand
720045
ProCore-Türbaugruppe komplett
609124
C2/C3 Hahnkuppel-Etikettensatz

Contact support for any required spares not listed above.

Alle Komponenten müssen von einem vom Hersteller autorisierten Techniker mit vom Hersteller genehmigten Komponenten (oben aufgeführt) ersetzt werden, um Gesundheits- und Sicherheitsrisiken durch elektrische Gefahren und Brandgefahr aufgrund falscher Teile oder unsachgemäßer Wartung zu minimieren.

Borg & Overström
Synergy House,
Fakenham Road,
Morton on the Hill,
UK
NR9 5SP