Sicherheit
Specification
Product specifications
Pre-installation information
For full instructions on preparing for your E4 water dispenser installation, download the pre installation sheet below.
Diagram showing minimum installation requirements.
What's in the box
E4 water dispenser
Contents:
1 x E4 unit
1 x Power cord set
1 x Drip tray and cover
1 x User guide
Countertop dimensions
Floorstanding dimensions
How-to-install video
Installation
Installation requirements
You will need:
- Installation kit, including water block and filter. Your kit will depend on your requirements and model. See installation kit guide here.
- Cordless drill
- Hole saw (Countertop units only)
- John Guest pipe cutters
- Adjustable spanner
- Side cutters
- Screwdriver
- 1L measuring jug
Countertop or Floorstanding?
The first step of your installation will depend on your water dispenser. If you have a countertop dispenser, begin with Section 1a. If you have a floorstanding dispenser, proceed directly to Section 1b.
To install a countertop E4 water dispenser, follow Section 1a.
To install a floorstanding E4 water dispenser, follow Section 1b.
Section 1a: Installing a countertop dispenser
Section 1b: Installing a floorstanding dispenser
CO2 bottle installation - sparkling models only
Make sure the regulator is off by twisting the top knob anti-clockwise before attaching to the CO2 bottle. Do not overtwist.
How to use
Control panel
Illuminated indicators
How to dispense water
Maintenance & cleaning
Sanitisation guide
You will need
- Measuring jug
- Protective gloves
- Hydrogen Peroxide (H202 3%) food safe sanitising solution
- Service filter cartridge
- Sanitising wipes
- Water filter
Care and maintenance of dispenser finish
Advanced setup
Advanced functions
Adjusting sparkling water flow rate
NOTE: Sparkling water flow rate factory setting = 1.8L (0.4 Gal) per minute MAX. This may need adjusting depending on inlet pressure. To do so follow below steps:
Sparkling models only
Advanced troubleshooting
Troubleshooting
Warning flash sequences
In the event of the warning triangle flashing please see the sequences below for diagnostics.
Emptying sparkling water
Draining the hot tank
If you are decommissioning a unit, or descaling the hot tank you must first drain the hot tank.
To do so proceed with the following steps:
Technical Information
E4 Chilled & Ambient circuit schematic
E4 Chilled, Sparkling & Ambient circuit schematic
E4 Chilled, Ambient & Hot circuit schematic
E4 Chilled, Sparkling & Hot circuit schematic
E4 Chilled & Ambient water pathway
E4 Chilled, Sparkling & Ambient water pathway
E4 Chilled, Ambient & Hot water pathway
E4 Chilled, Sparkling & Hot water pathway
Spares
Dispenser exploded parts diagram
Safety critical spares
2 bar PRV 8mm
703144
2:1 Dosiermagnetventil 8 mm
2:1 Dispense Solenoid Valve 8mm UL
703235
3:1 Dosiermagnetventil 8 mm
3:1 Dispense Solenoid Valve 8mm UL
703236
8mm PF-Magnetventil 24VDC
8mm Push Fit Solenoid Valve 24VDC UL
703234
Kühllüfter 24 V mit Kabelbaum
Membran-Druckerhöhungspumpe – Sprudelwasserpumpe mit geringer Durchflussrate, 115 V
Membran-Druckerhöhungspumpe – Sprudelwasserpumpe mit geringer Durchflussrate, 230 V
Warmwasserspeicher der E-Serie, 115 V
Warmwasserspeicher der E-Serie, 230 V
E4 Kühl- und Umgebungs-Touch-Bedienfeld (HMI)
E4 Kühl-, Raumtemperatur- und Heiß-Touch-Bedienfeld (HMI)
E4 Gekühlte, prickelnde und Umgebungs-Touch-Bedienfeldbaugruppe (HMI)
E4 Kühl-, Sprudel- und Heißgetränke-Touch-Bedienfeldbaugruppe (HMI)
E4 Dosierverteilerauslass
E4 Hardware Electronics PCB Version 3.6 230v
702546
Sensorkabelsatz E4
Durchflussbegrenzer 8mm - 8mm JG - Nylon
Einzelnes Rückschlagventil 1/4" Steckverbindung
Einzelrückschlagventil 5/16" (8mm) PF
Solenoid Loom E4
702539
Sprudelwasser-Durchflussregelventil
Cosmetic spares
Contact support for any required spares not listed above.