Safety
Specification
Product specifications
Pre-installation information
For full instructions on preparing for your E6 water dispenser installation, download the pre installation sheet below.
Diagram showing minimum installation requirements.
What's in the box
E6 water dispenser
Contents:
1 x E6 unit
1 x Power cord set
1 x Drip tray and cover
1 x User guide
Countertop dimensions
Floorstanding dimensions
How-to-install video
Installation
Installation requirements
You will need:
- Installation kit, including water block and filter. Your kit will depend on your requirements and model. See installation kit guide here.
- Cordless drill
- Hole saw (Countertop units only)
- John Guest pipe cutters
- Adjustable spanner
- Side cutters
- Screwdriver
- 1L measuring jug
Countertop or Floorstanding?
The first step of your installation will depend on your water dispenser. If you have a Countertop dispenser, begin with Section 1a. If you have a Floorstanding dispenser, proceed directly to Section 1b.
To install a countertop E6 water dispenser, follow section 1a.
To install a floorstanding E6 water dispenser, follow section 1b.
Section 1a: Installing a countertop dispenser
*Expect dripping on hot dispense until the tank has reached temperature and initial dispense made. This will only occur on first heating cycle on initial start-up.
Section 1b: Installing a floorstanding dispenser
*Expect dripping on hot dispense until the tank has reached temperature and initial dispense made. This will only occur on first heating cycle on initial start-up.
CO2 bottle installation - sparkling models only
Make sure the regulator is off by twisting the top knob anti-clockwise before attaching to the CO2 bottle. Do not overtwist.
How to use - Standard dispenser
Control panel
Illuminated indicators
How to dispense water
How to use - Measured Dispense
Control panel
How to dispense water
Maintenance & cleaning
Sanitisation guide
You will need
- Measuring jug
- Protective gloves
- Hydrogen Peroxide (H202 3%) food safe sanitising solution
- Service filter cartridge
- Sanitising wipes
- Water filter
Care and maintenance of dispenser finish
Advanced setup
Advanced functions
These functions are only adjustable within 10 minutes from start-up. To adjust the hot water recover dispense control or the hot water temperature selection, you must be in commissioning mode.
Adjusting sparkling water flow rate
NOTE: Sparkling water flow rate factory setting = 1.8L (0.4 Gal) per minute MAX. This may need adjusting depending on inlet pressure. To do so follow below steps:
Sparkling models only
Advanced troubleshooting
Troubleshooting
Warning flash sequences
In the event of the warning triangle flashing please see the sequences below for diagnostics.
Emptying sparkling water
Draining the hot tank
If you are decommissioning a unit, or descaling the hot tank you must first drain the hot tank.
To do so proceed with the following steps:
Technical information
E6 Chilled Only circuit schematic
E6 Chilled & Ambient circuit schematic
E6 Chilled, Sparkling & Ambient circuit schematic
E6 Chilled, Ambient & Hot circuit schematic
E6 Chilled, Sparkling, Ambient & Hot circuit schematic
E6 Chilled Only water pathway
E6 Chilled & Ambient water pathway
E6 Chilled & Sparkling (Measured) water pathway
E6 Chilled, Sparkling & Ambient water pathway
E6 Chilled, Ambient & Hot water pathway
E6 Chilled, Sparkling, Ambient & Hot water pathway
Spares
Dispenser exploded parts diagram
Safety critical spares
PCBA Main Control Board Assembly
720337
Measured Dispense PCBA Main Control Board Assembly
720800
E6 LED board
700154
Cooling Fan 24v with Loom
702558
Diaphragm Booster Pump - Low Flow Rate Sparkling Water Pump 115v
702800
Diaphragm Booster Pump - Low Flow Rate Sparkling Water Pump 230v
702770
E-series Hot Water Tank 115v
702317
E-series Hot Water Tank 230v
702488
FS-16 Flow Switch
702078
E6 Chilled Only Touch Control Panel (HMI)
720936
E6 Chilled & Ambient Touch Control Panel (HMI)
720295
E6 Chilled & Sparkling Measured Dispense Touch Control Panel (HMI)
720932
E6 & T3 Chilled, Ambient & Hot Touch Control Panel (HMI)
720365
E6 & T3 Chilled, Sparkling, Ambient & Hot Touch Control Panel Assembly (HMI)
720372
E6 Chilled, Sparkling & Ambient Touch Control Panel Assembly (HMI)
720289
Temperature Probe
720023
All-in-one Sensor Loom with KK Connectors
702878
PCBA Main Board Solenoid loom
702787
90-Degree Solenoid Valve - 3/4” BSP x 8mm Push-Fit connection for E6 & E7
701588
Flow restrictor 8mm - 8mm JG - nylon
702146
8mm PF Solenoid Valve 24VDC
701729
2:1 Dispense Solenoid Valve 8mm
701937
3:1 Dispense Solenoid Valve 8mm
701992
Solenoid 3/4” BSP 8mm UL
703237
90-Degree Solenoid Valve - 3/4” BSP x 8mm Push-Fit connection UL
703233
8mm Push Fit Solenoid Valve 24VDC UL
703234
3:1 Dispense Solenoid Valve 8mm UL
703236
2:1 Dispense Solenoid Valve 8mm UL
703235
Flow sensor 0.5 - 7 L/min 8mm
702891
Sparkling Water Flow Control Valve
637329
Single Check Valve 5/16" (8mm) PF
462667
Single Check Valve 1/4" Push Fit
462668
Cosmetic spares
Contact support for any required spares not listed above.
Borg & Overström
Synergy House,
Fakenham Road,
Morton on the Hill,
UK
NR9 5SP