Safety
Specification
Product specifications
Pre-installation information
Diagram showing minimum installation requirements.
Cutting templates
What's in the box
Product front view
Contents:
1 x T1 Tap
1 x Driptray (optional)
1 x 1.0m x 6mm Insulated Water Pipe
1 x Connector Cable
1 x Earth Wire
1 x Waste Drain Pipe (optional)
1 x Fixings Set
1 x Tap Cutting Guide
1 x ProCore Unit
1 x Power Cord Set
1 x DeepSparkle Kit (Sparkling models only)
1 x Simple-fit Ventilation Kit
Product rear view
Dimensions
How-to-install video
Installation
Installation requirements
Identify a suitable location for the ProCore® undercounter unit. It should be positioned within 1.0m of the tap, and within 2.0m of suitable services connections. Ensure to allow enough space for the Simple-fit Vent Kit which must be installed with the unit. See Pre-Installation guide here for full installation requirements before proceeding with installation.
We recommend using an installation kit, which includes everything needed to complete the installation.
You will need:
- Installation kit, including water block and filter. Your kit will depend on your requirements and model. See installation kit guide here.
- Water block
- Installation Kit
- Jigsaw
- 35mm hole saw
- 160mm hole saw (optional)
- Cordless drill
- John Guest pipe cutters
- Adjustable spanner
- Side cutters
- Screwdriver
- Allen key set
- 1L measuring jug
Where will your tap be installed?
The first step of your installation will depend on were you are installing your tap system. If you are installing with sink drainage, begin with Section 1a. If you are installing with drip tray drainage, proceed directly to Section 1b.
To start the installation of a T1 tap system with sink drainage, follow Section 1a.
To start the installation of a T1 tap system with drip tray drainage, proceed directly to Section 1b.
Section 1a - Installing a tap with sink drainage
Section 1b - Installing a tap with drip tray drainage
Section 2 - Installing the undercounter ProCore and Simple-Fit vent kit
This operation must only be carried out by trained staff.
Section 3 - Connecting the tap to the ProCore
CO2 bottle installation - Sparkling models only
Make sure the regulator is off by twisting the top knob anti-clockwise before attaching to the CO2 bottle. Do not overtwist.
How to use
Tap control panel
Illuminated indicators
How to dispense water
Maintenance & cleaning
Sanitisation guide
You will need
- Measuring jug
- Protective gloves
- Hydrogen Peroxide (H202 3%) food safe sanitising solution
- Service filter cartridge
- Sanitising wipes
- Water filter
Care and maintenance of tap finish
Advanced setup
Certain features can be adjusted by a trained installer as part of the product set up.
Advanced settings
Adjusting sparkling water flow rate
NOTE: Sparkling water flow rate factory setting = 1.8L (0.4 Gal) per minute MAX. This may need adjusting depending on inlet pressure. To do so follow below steps:
Sparkling models only
Advanced troubleshooting
Troubleshooting
Warning flash sequences
In the event of the warning light flashing, please see the sequences below for diagnostics.
Emptying sparkling water
Technical information
T1 Chilled & Ambient circuit schematic
T1 Chilled & Sparkling circuit schematic
T1 Chilled, Ambient & Sparkling circuit schematic
T1 Chilled & Ambient water pathway
T1 Chilled & Sparkling water pathway
T1 Chilled, Ambient & Sparkling water pathway
Spares
ProCore exploded parts diagram
T1 exploded parts diagram
Safety critical spares
PCBA Main Board Solenoid loom
702787
Diaphragm Booster Pump - Low Flow Rate Sparkling Water Pump 115v
702800
Diaphragm Booster Pump - Low Flow Rate Sparkling Water Pump 230v
702770
Cooling Fan 24v with Loom
702558
FS-16 Flow Switch
702078
Solenoid 3/4” BSP 8mm PF
701094
2:1 Dispense Solenoid Valve 8mm
701937
3:1 Dispense Solenoid Valve 8mm
701992
Single Check Valve 5/16" (8mm) PF
462667
Single Check Valve 1/4" Push Fit
462668
Solenoid 3/4” BSP 8mm UL
703237
3:1 Dispense Solenoid Valve 8mm UL
703236
2:1 Dispense Solenoid Valve 8mm UL
703235
90-Degree Solenoid Valve - 3/4” BSP x 8mm Push-Fit connection UL
703233
Temperature Probe
720023
All-in-one Sensor Loom with KK Connectors
702878
T1 Chilled & Ambient Touch Control Panel Assembly - Link SW (HMI & Main Board)
720986
T1 Chilled & Sparkling Touch Control Panel Assembly - Link SW (HMI & Main Board)
720985
T1 Chilled, Sparkling & Ambient Touch Control Panel Assembly - Link SW (HMI & Main Board)
720984
PCBA Main Control Board Assembly
720337