Accéder au contenu

T2 Install & Operation Manual

Partager le manuel Retour

Sécurité

This appliance can be used by adults and children aged 8 and above, as well as people with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, as long as they have been given instruction or supervision concerning the use of the appliance in a safe way and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be conducted by children.

The appliance shall only be maintained and repaired by authorized technicians who are properly trained and certified. The appliance should be isolated from the electricity supply before removal of any covers. Great care must be employed when working with high pressure carbon dioxide, and in no cases should the maximum operating pressure of 0.4MPa (4 bar) be exceeded.

  • The appliance must be placed upright on a flat horizontal surface.
  • The appliance must be kept away from sunlight, heat and moisture.
  • The appliance shall not be placed in lobbies or locations of egress or where it may obstruct exit access.
  • The appliance must be installed in an environment free of dust and corrosive/explosive gases.
  • The appliance is not suitable for installation in an area where a water jet could be used.
  • The appliance must not be installed where it is liable to freeze. If the unit is thought to be frozen it must not be switched on.
  • The appliance must maintain adequate mechanical stability when in use, during transportation, assembly, dismantling, scrapping and any other action.
  • The appliance must not be installed without a waterblock. Installing without a waterblock will invalidate warranty.
  • The appliance must have adequate ventilation. Installing the unit without the Simple-fit Vent Kit will invalidate the warranty.

WARNING: Keep ventilation openings in the appliance enclosure or in the built-in structure clear of obstruction.
WARNING: When positioning the appliance, ensure the supply cord is not trapped or damaged.
WARNING: Do not locate multiple portable socket-outlets or portable power supplies at the rear of the appliance.
WARNING: Increased risk of a leak could occur through improper handling, movement or use.

The appliance must be installed in accordance with the relevant requirements of:

  • The appropriate building regulations by application of either The Building Regulations (England and Wales), The Building Regulations (Scotland) or The Building Regulations (Northern Ireland). In territories other than those listed the local regulations in force must be complied with.
  • The Water Supply (Water Fittings) Regulations (England, Wales and Northern Ireland) or The Water Byelaws in Scotland.

This appliance is designed for dispensing drinking water in commercial and workplace environments, including:

  • Offices and corporate workplaces
  • Factories and industrial staff welfare areas
  • Hotels, hostels, and other hospitality environments
  • Public buildings such as schools, hospitals, and leisure facilities
  • Household environments and similar applications.

The appliance is suitable for providing chilled and/or heated potable drinking water for employees, visitors, and guests.

The appliance is intended for indoor use only and must be installed and operated in accordance with the instructions provided in this manual.

Restrictions on Use
  • This appliance is not intended for heavy industrial use or continuous high-demand applications beyond its specified capacity.
  • It must only be used for dispensing potable (drinkable) water.
  • Do not use the appliance for any purpose other than that for which it is intended.
Message de sécurité R290

Le R290 est un gaz propane de qualité réfrigérante utilisé dans une large gamme d'unités de réfrigération commerciale et de climatisation. Propane de haute pureté, il a un faible impact environnemental et un potentiel de réchauffement global (PRG) nominal, ce qui signifie qu'il ne possède aucune propriété destructrice pour la couche d'ozone. Le R290 est également l'alternative hydrocarbonée préférée par l'Agence de Protection de l'Environnement (EPA), remplaçant des réfrigérants fluorocarbonés plus nocifs comme le R22, le R134a, le R404a et le R502. Les unités utilisant le R290 ne peuvent être entretenues et réparées que par des techniciens autorisés, correctement formés et certifiés.

Déchets d'appareils électriques

En tant que producteur soumis à la réglementation britannique WEEE, Borg and Overström respecte ses obligations de producteur en étant inscrit en tant que membre d'un schéma de conformité WEEE et en détenant un numéro d'enregistrement de producteur WEEE. Ce produit est conçu et fabriqué avec des matériaux pouvant être recyclés et réutilisés. Le symbole signifie que le produit doit être éliminé séparément des déchets ménagers en fin de vie.
Numéro d'enregistrement WEEE du producteur : WEE/KG0136ZT

Specification

Product specifications

230V

115V

Water options

Chilled, Sparkling and Ambient
*Your water options will vary depending on your model.

Chilled, Sparkling and Ambient
*Your water options will vary depending on your model.

Système

Système de refroidissement DryChill®
Technologie de refroidissement rapide hygiénique. Noyau en aluminium massif avec serpentin de refroidissement en acier inoxydable hygiénique. Utilise le gaz éco-réfrigérant R290.

Système de refroidissement DryChill®
Technologie de refroidissement rapide hygiénique. Noyau en aluminium massif avec serpentin de refroidissement en acier inoxydable hygiénique. Utilise le gaz éco-réfrigérant R290.

Hygiène

Totalité
Méthodologie d'hygiène en 5 étapes

Viovandt (modèles sélectionnés uniquement)
Technologie LED UV-C écologique

Totalité
Méthodologie d'hygiène en 5 étapes

Viovandt (modèles sélectionnés uniquement)
Technologie LED UV-C écologique

Technologie

DeepSparkle (modèles sélectionnés uniquement)
Eau pétillante avec une effervescence durable

MonoFit (modèles sélectionnés uniquement)
Une police à ajustement simple pour une installation au robinet facile et non invasive.

EcoMode
Technologie d'économie d'énergie.

DeepSparkle (modèles sélectionnés uniquement)
Eau pétillante avec une effervescence durable

MonoFit (modèles sélectionnés uniquement)
Une police à ajustement simple pour une installation au robinet facile et non invasive.

EcoMode
Technologie d'économie d'énergie.

Gaz réfrigérant

Utilise le gaz éco-réfrigérant R290.

Utilise le gaz éco-réfrigérant R290.

Commandes opérationnelles

Panneau tactile capacitif avec protection antimicrobienne.

Panneau tactile capacitif avec protection antimicrobienne.

Hauteur de distribution

310 mm

12.2"

Dimensions

Tap
W160 x D324 x H390mm

Undercounter ProCore®
W320 x D430 x H375mm

Tap
W6.3 x D12.8 x H15.5"

Undercounter ProCore®
W12.5 x D17 x H15.5"

Alimentation électrique

230-240V~ AC (50Hz)

110-120V~ CA (60Hz)

Indice de fusible

10A

10A

Température Fraîche et Pétillante

À partir de 2°C

À partir de 2°C

Capacité Réfrigérée et Pétillante

80L

21 gal US/h

Maximum running power consumption

Chilled and ambient
0.2kW-230V

Chilled and sparkling
0.3kW-230V

Chilled, sparkling and ambient
0.3kW-230V

Chilled and ambient
0.18kW-110V

Chilled and sparkling
0.24kW-110v

Chilled, sparkling and ambient
0.24kW-110v

Rated current

Chilled and ambient
1.5A

Chilled and sparkling
1.7A

Chilled, sparkling and ambient
1.7A

Chilled and ambient
2A

Chilled and sparkling
2.6A

Chilled, sparkling and ambient
2.6A

Gaz de réfrigération

R290 40g

R290 37g

Weight

Max
22Kg

Max
59.5lbs

Raccord d'entrée d'eau

3/4" BSP

3/4" BSP

Température de l'eau d'entrée

Jusqu'à 25°C

Jusqu'à 25°C

Inlet water pressure

Min
0.05MPa (0.5 bar)

Max
1.0 MPa (10 bar)

Min
7.3psi (0.05MPa)

Max
145psi (1.0 MPa)

Outlet water pressure

Internally regulated to 0.2 MPa (2 bar)

Internally regulated to 29psi (0.2 MPa)

Connexion CO2

Raccord à emboîtement 1/4”

Raccord à emboîtement 1/4”

Pression CO2

Max
0,4MPa (4 Bar)

Max
58 psi (0,4 MPa)

Température de fonctionnement de la chambre

Min
16°C

Max
32°C

Min
16°C

Max
32°C

Classe climatique

N

N

Conformité DDA

Commandes tactiles accessibles à l'avant de l'appareil.

Commandes tactiles accessibles à l'avant de l'appareil.

Niveau sonore d'émission

Max
70 dB(A)

Max
70 dB(A)

Pre-installation information

Prior to installing the T2 tap and ProCore undercounter unit, ensure the following requirements are met:

  • Minimum cupboard size of 500mm x 500mm x 500mm
  • Drip tray cut-out of 146 x 311mm (60mm hole for MonoFit). View cutting templates
  • Minimum clearance of 460mm.
  • Vent kit cut-out of 300 x 30mm (allow clearance of 45mm each side). View cutting templates
  • Worktop thickness of 20 to 70mm.
  • 10A power supply within 1.8m of the unit.
  • Mains supply potable water within 2m of the unit.
  • Mains waste kit (included) or Bluetooth waste kit (optional).

Diagram showing minimum installation requirements.

Cutting templates

Chaque système de robinet est livré avec un ensemble de gabarits de découpe pour faciliter l'installation. Si vous souhaitez découper votre plan de travail ou votre meuble bas avant la livraison de votre système de robinet, vous pouvez commander un gabarit de découpe à l'avance.

Nos gabarits de découpe imprimés sont à taille réelle pour garantir une découpe précise. Nous déclinons toute responsabilité concernant les dimensions d’un PDF téléchargé et imprimé par un tiers.

Modèle de découpe pour base de ventilation ProCore® Simple-fit

Nous vous recommandons de vérifier les dimensions du kit de ventilation ProCore Simple-fit à l'aide du gabarit de découpe avant de découper le meuble bas.

Modèle standard de découpe pour robinet et bac d'égouttage

Nous vous recommandons de vérifier les dimensions du robinet et du bac d'égouttage à l'aide du gabarit de découpe avant de découper le plan de travail.

Gabarit de découpe MonoFit pour robinet et bac d'égouttage

Nous vous recommandons de vérifier les dimensions du robinet et du bac d'égouttage à l'aide du gabarit de découpe avant de découper le plan de travail.

What's in the box

Kits d'installation et filtres ne sont PAS inclus et sont fournis en tant qu'articles supplémentaires selon les besoins spécifiques de commande.
Achetez maintenant

Product front

Contents:
1 x T2 Tap
1 x Baseplate (Standard or MonoFit)
1 x Drip Tray
1 x 1.0m x 6mm Insulated Water Pipe
1 x Connector Cable
1 x Earth Wire
1 x Waste Drain Pipe
1 x Fixings Set
1 x Baseplate Cutting Guide
1 x ProCore Unit
1 x Power Cord Set
1 x DeepSparkle Kit (Sparkling models only)
1 x Simple-fit Ventilation Kit

Product rear

Kits d'installation et filtres ne sont PAS inclus et sont fournis en tant qu'articles supplémentaires selon les besoins spécifiques de commande.
Achetez maintenant

Dimensions

How-to-install video

Installation

The Borg & Overström Simple-fit Vent Kit must be used during installation. Failure to do so will invalidate the warranty for that unit.
Shop Ventilation Kits

Un bloc d'eau doit être installé avec chaque unité. Le non-respect de cette consigne annulera la garantie de cette unité. Ceux-ci sont inclus dans nos kits d'installation.
Acheter des blocs d'eau

Installation requirements

230V

115V

Water

Mains potable water
Inlet water pressure from 0.05MPa (0.5 bar) - 1.0 MPa (10 bar)

Mains potable water
Inlet water pressure from 7.3psi (0.05MPa) - 145psi (1.0MPa)

Température ambiante de fonctionnement de la pièce

Min
16°C

Max
32°C

Min
16°C

Max
32°C

CO₂

CO₂ de qualité alimentaire à fournir

CO₂ de qualité alimentaire à fournir

Électricité

Alimentation 10A - Protection contre les fuites à la terre

Alimentation 10A - Protection contre les fuites à la terre (Pour les États-Unis et le Canada, l'alimentation doit être protégée par un disjoncteur différentiel à haute sensibilité (GFCI))

Déchets

Raccordement de vidange principale ou kit de déchets Bluetooth

Raccordement de vidange principale ou kit de déchets Bluetooth

Identify a suitable location for the ProCore® undercounter unit. It should be positioned within 1.0m of the tap, and within 2.0m of suitable services connections. Ensure to allow enough space for the Simple-fit Vent Kit which must be installed with the unit. See Pre-Installation guide here for full installation requirements before proceeding with installation.

We recommend using an installation kit, which includes everything needed to complete the installation.

You will need:

  • Installation kit, including water block and filter. Your kit will depend on your requirements and model. See installation kit guide here.
  • Water block
  • Installation Kit
  • Jigsaw
  • Hole saw (MonoFit® models only)
  • Cordless drill
  • John Guest pipe cutters
  • Adjustable spanner
  • Side cutters
  • Screwdriver
  • Allen key set
  • 1L measuring jug

Standard or MonoFit?

The first step of your installation will depend on your tap system. If you have a Standard tap system, begin with Section 1a. If you have a MonoFit tap system, proceed directly to Section 1b.

Standard T2 tap system

To start the installation of a standard T2 tap system, follow Section 1a.

T2 MonoFit® tap system

To start the installation of a MonoFit tap system, proceed directly to Section 1b.

Section 1a - Installing a standard countertop tap system

1

La section suivante s'applique uniquement à l'installation de robinets standard. Si vous installez un robinet MonoFit, passez à la section 1b.
Cette opération doit être effectuée uniquement par du personnel formé.

2

Identifiez un emplacement approprié pour le robinet. Assurez-vous que le plan de travail est de niveau pour permettre l'évacuation du système et qu'il n'y a aucun obstacle en dessous.

3

Assurez-vous qu'il y a suffisamment d'espace dans le placard sous l'emplacement du robinet (500 × 500 mm) pour installer l'unité ProCore. Veillez à ce que l'accès aux fixations de l'isolateur de service pour l'eau et l'électricité soit dégagé, et laissez suffisamment d'espace pour le filtre à eau et la cartouche de CO₂ sur les modèles pétillants.

4

Also allow 460mm for the height of the tap under any overhanging cupboard/shelf.

5

Placez un morceau de ruban adhésif sur le bord du plan de travail et marquez le centre du bac à gouttes.

6

Positionnez le gabarit de découpe à la distance souhaitée du bord de la surface de travail, puis fixez-le en place. Assurez-vous que le centre soit aligné avec votre marque sur le ruban adhésif.

7

Percez les quatre trous d'angle du bac d'égouttement avec un foret de 10 mm.

8

Retirez le gabarit et enlevez toute la sciure.

9

À l'aide de ruban adhésif de masquage et d'une règle droite, tracez les lignes directrices entre les quatre trous du bac d'égouttement.

10

À l'aide d'une scie sauteuse, découpez soigneusement le long des lignes et retirez la pièce de surface de travail inutilisée.

11

Nettoyez toute la sciure et assurez-vous que la surface soit propre et sèche.

12

Join the faucet to the baseplate. Ensure the tap outlet is positioned centrally over the drip tray below.

13

Insert the tap so the fixing screws line up with the indentations. Tighten up the M4 hex screws with an Allen key until the tap is secure. Do not overtighten.

14

Position the drip tray squarely into the cutout, ensuring the front edge is parallel with the front of the work surface. Add additional sealant, if required, to ensure a watertight seal.

15

En utilisant les 4 tiges filetées M6 fournies, placez-les à la base du robinet.

16

Next connect the earth wire on one of the bars with the star washer beneath it (attach the other end to one of the screws on the back of the ProCore when installed). Then, tighten till secure using the flange nuts provided.

17

Fit the waste pipe and secure with the jubilee clip. Connect to the drain or Bluetooth alarmed waste kit ensuring there is a constant fall.

Section 1b - Installing a MonoFit tap system

1

La section suivante s'applique uniquement à l'installation du robinet MonoFit. Si vous installez un robinet Standard, complétez la Section 1a et passez à la Section 2.
Cette opération doit être réalisée uniquement par du personnel formé.

2

Identifiez un emplacement approprié pour le robinet. Assurez-vous que le plan de travail est de niveau pour permettre l'évacuation du système et qu'il n'y a aucun obstacle en dessous.

3

Assurez-vous qu'il y a suffisamment d'espace dans le placard sous l'emplacement du robinet (500 × 500 mm) pour installer l'unité ProCore. Veillez à ce que l'accès aux fixations de l'isolateur de service pour l'eau et l'électricité soit dégagé, et laissez suffisamment d'espace pour le filtre à eau et la cartouche de CO₂ sur les modèles pétillants.

4

Also allow 460mm for the height of the tap under any overhanging cupboard/shelf.

5

Position the cutting template the desired distance away from the edge of the work surface.

6

Place two pieces of masking tape either side of the bottom line (labelled 1B) on the cutting template. Using a straight edge, mark along line 1B continuing onto both pieces of masking tape.

7

Secure the cutting template into place.

8

Drill the access hole for the drip tray, using a 60mm circular drill bit.

9

Remove the cutting template, leaving the two pieces of masking tape either side of the drip tray. Clean away any sawdust.

10

Join the faucet to the baseplate. Ensure the tap outlet is positioned centrally over the drip tray below.

11

Insert the tap so the fixing screws line up with the indentations. Tighten up the M4 hex screws with an Allen key until the tap is secure. Do not overtighten.

12

Position the drip tray into the cutout, ensuring the front edge is parallel with the marked pieces of masking tape. Add additional sealant, if required, to ensure a watertight seal.

13

En utilisant les 4 tiges filetées M6 fournies, placez-les à la base du robinet.

14

Next connect the earth wire on one of the bars with the star washer beneath it (attach the other end to one of the screws on the back of the ProCore when installed). Then, tighten till secure using the flange nuts provided.

15

Fit the waste pipe and secure with the jubilee clip. Connect to the drain or Bluetooth alarmed waste kit ensuring there is a constant fall.

Section 2 - Installing the undercounter ProCore and Simple-Fit vent kit

Avant de faire des découpes dans le placard ou la plinthe, assurez-vous que la zone à découper est exempte de tuyaux d'eau ou de câbles électriques. Il y a un risque de blessure grave ou de décès si des câbles électriques sont coupés, et des dommages importants aux biens si un tuyau d'eau est sectionné.

1

This operation must only be carried out by trained staff.

2

Décidez où vous souhaitez placer le ProCore, au centre ou sur un côté du placard. Vous aurez besoin de suffisamment d'espace pour une cartouche de CO₂ (modèles pétillants uniquement) et un filtre à eau. Assurez-vous de laisser un espace d'au moins 45 mm de chaque côté du ProCore®.

3

En utilisant le gabarit de découpe fourni, pliez le long de la ligne latérale appropriée, puis pliez le long du bord avant et fixez avec du ruban adhésif.

4

Prenez une mèche à bois de dix millimètres et percez les deux trous de guidage indiqués sur le gabarit.

5

Supprimez le modèle.

6

Appliquez du ruban adhésif de masquage pour protéger et tracez des lignes prêtes à être découpées.

7

Utilisez une scie sauteuse pour découper soigneusement le long des lignes en prenant soin de ne pas endommager le socle.

8

Retirez le ruban adhésif de masquage et enlevez la sciure.

9

Placez la base de ventilation Simple-fit au centre de l'ouverture. Assurez-vous qu'il y ait un espace d'air d'au moins 30 mm de chaque côté.

10

Line up the vent flue chimney with the backplate. Then place over the slots and slide downwards into place.

11

Lower the ProCore® carefully into position on the ventilation base to ensure the rear vent duct is located correctly in Simple Fit vent Flue at the rear of the base.

12

Assurez-vous que les évents ne sont pas obstrués. Toute obstruction affectera négativement le flux d'air vers l'appareil, ce qui pourrait entraîner une mauvaise performance, une surchauffe ou une panne du réfrigérateur.

Section 3 - Connecting the tap to the ProCore

1

Installez le bloc d'eau. Ne pas le faire annulera la garantie de cette unité.

2

Install the installation kit into the cupboard. Leave room for the filters to be changes when required.

3

Connect the filter to the mains water supply. Use locking clips on each connection for security.

4

Using the measuring jug, turn on the water supply and flush the filters to waste until it runs clear.

5

Using the 3/4 inch BSP fitting, connect the filter to the unit.

6

Using the blue chilled water pipe, slide on the provided black insulation and connect to the chilled water outlet.
NOTE: To improve sparkling anti-drip, cut pipes to the shortest length possible, but ensuring they are not taught.

7

Retirez la connexion USB sous le robinet et branchez-la sur le port USB à l'arrière de l'unité ProCore® sous le comptoir.

8

Attach the other end of the earth wire, with the star washer beneath it, to one of the screws on the back of the ProCore® unit.

9

Si vous avez un modèle pétillant, connectez l'alimentation en CO2 depuis le régulateur de gaz et suivez la section d'installation du CO2 ci-dessous.

10

Connect the unit to the electricity supply and switch on.

11

Sparkling models should have the carbonator purged of air by activating the sparkling water dispense for approximately 10 seconds.

12

Ouvrez l'alimentation en eau.

13

Allow the machine to stand for 10 minutes for the initial chilling process to complete.

14

Flush water through each dispense option. Ensure everything functions correctly and is clean.

15

We recommend that the unit undergoes a sanitisation procedure. You can follow the instructions below. Your unit is now ready for use.

CO2 bottle installation - Sparkling models only

1

Cette opération doit être effectuée uniquement par du personnel formé.

2

Déballez le régulateur de CO2 et fixez le raccord coudé à la sortie du robinet.

3

Make sure the regulator is off by twisting the top knob anti-clockwise before attaching to the CO2 bottle. Do not overtwist.

4

Fixez le régulateur à la bouteille de CO2 jetable, en veillant à ce que la petite soupape de décharge de pression sur la tige soit orientée à l'opposé de vous et des autres. Serrez à la main de manière sécurisée.

5

Connect the assembled CO2 bottle and regulator to the CO2 inlet using a ¼” pipe. Add a locking clip at either end to secure in place.

6

Stand the cylinder upright in a suitable location.

7

Réglez la pression de CO₂ sur le manomètre en tournant manuellement le bouton supérieur jusqu'à ce que le manomètre indique 3,5 - 4 bars (58 PSI). Ne dépassez pas une pression de 4 bars.

How to use

Tap control panel

Model shown with chilled, sparkling and ambient water options. Other models may vary.

Illuminated indicators

EcoMode: EcoMode will activate in the instance of dispense inactivity or low light levels, identified by the EcoMode symbol being illuminated.

Chilled and sparkling water icon pulsing: Unit is chilling down.

Warning symbol: 'Warning triangle' will illuminate and flash when fault is present.

How to dispense water

  • To dispense water press desired water option icon and hold. Release to finish dispensing.

Maintenance & cleaning

Sanitisation guide

Le produit est livré de l'usine en état propre, mais nous recommandons d'effectuer une procédure de désinfection lors de l'installation, conformément aux instructions de désinfection ci-dessous. Nous recommandons de répéter la désinfection tous les 6 mois.

Le non-respect de l'utilisation des matériaux et des procédés de désinfection approuvés et/ou recommandés par Borg & Overström pourrait annuler votre garantie.
Contactez-nous pour plus d'informations

You will need

  • Measuring jug
  • Protective gloves
  • Hydrogen Peroxide (H202 3%) food safe sanitising solution
  • Service filter cartridge
  • Sanitising wipes
  • Water filter

1

Cette opération doit être effectuée uniquement par du personnel formé.

2

Une procédure de désinfection est recommandée tous les 6 mois.

3

Coupez l'arrivée d'eau principale.

4

Appuyez brièvement sur le bouton de distribution d'eau froide pour libérer la pression interne de l'eau dans la machine.

5

Retirez le filtre existant.

6

Utilisez du gel pour les mains et mettez des gants de protection.

7

Ajoutez 25 ml (environ 1 fl oz US) de solution désinfectante de peroxyde d'hydrogène (H2O2 3 %) dans une cartouche de filtre de service propre et vide.

8

Connectez-vous à la tête de filtre.

9

Ouvrez l'arrivée d'eau et laissez la cartouche du filtre de service se remplir.

10

Distribuez de l'eau en utilisant le bouton d'eau froide. Répétez avec les boutons d'eau pétillante et d'eau ambiante.

11

Laissez la solution à l'intérieur de la machine pour que la désinfection prenne effet (minimum 5 minutes) tout en nettoyant soigneusement le distributeur à l'extérieur.

12

Faites particulièrement attention au robinet de distribution et aux boutons-poussoirs. Pour cela, utilisez un désinfectant externe et des lingettes désinfectantes. 

13

Nettoyez le bac d'égouttement. Si un système de débordement des déchets est installé, videz-le et rincez-le avec une petite quantité de liquide désinfectant si nécessaire.

14

Essuyez les marques cosmétiques si nécessaire. Pour cela, nous recommandons d'utiliser de l'eau tiède savonneuse.

15

Reconnectez l'alimentation et allumez le distributeur.

16

Une fois le nettoyage externe terminé, faites passer 10 L (environ 4 1/4 pintes US) d'eau à travers chaque option de distribution (Froid, Pétillant, Ambiant).

17

Coupez l'eau et appuyez brièvement sur le bouton de distribution d'eau froide pour libérer la pression interne de l'eau dans la machine.

18

Supprimez le filtre de service. Conservez le filtre de service pour une réutilisation.

19

Installez un nouveau filtre et ouvrez l'arrivée d'eau.

20

Rincez d'abord le nouveau filtre à l'eau usée en utilisant le bouton refroidi jusqu'à ce que 5 L (environ 2 pintes US) d'eau aient été évacués. Répétez cette opération pour toutes les options de distribution. Votre distributeur est maintenant prêt à être utilisé.

Care and maintenance of tap finish

Les finitions sont généralement faciles à entretenir et conservent leur aspect avec un minimum d'effort. Cependant, un nettoyage et un entretien réguliers garantiront leur longévité et leur apparence esthétique.

L'appareil doit avoir l'objectif nettoyé au moins une fois par semaine avec un nettoyant pour écran – assurez-vous que l'appareil est éteint pendant le nettoyage.

Pour de meilleurs résultats, polissez le distributeur avec un chiffon doux si nécessaire, dès que des signes de saleté ou de traces apparaissent. Un nettoyage hebdomadaire avec un chiffon humide utilisant un savon doux et de l'eau est recommandé pour maintenir la brillance et enlever les empreintes digitales. Séchez et polissez avec un chiffon doux.

AVERTISSEMENT : Une utilisation inappropriée des nettoyants et stérilisateurs ou une exposition à des produits chimiques puissants peut provoquer corrosion, taches et décoloration. Évitez les agents nettoyants abrasifs ou agressifs qui peuvent endommager la finition.

Veuillez noter que la contamination de la surface et l'environnement environnant peuvent accélérer les taches et la décoloration, par exemple dans les environnements marins où le sel est présent ou dans les endroits à forte humidité.

Advanced setup

Certain features can be adjusted by a trained installer as part of the product set up.

Advanced settings

Mode Éco

Appuyez sept fois sur l'icône de l'eau froide et maintenez la pression lors de la septième fois. Deux bips indiquent que c'est activé et un bip indique que c'est désactivé.

Kit de déchets Bluetooth

Appuyez cinq fois sur l'icône refroidie et maintenez la pression sur la cinquième. Deux bips indiquent que c'est activé et un bip indique que c'est désactivé.

Amélioration anti-goutte pour eau pétillante

Retirez le fil de liaison rouge, puis touchez l'icône scintillante 10 fois en maintenant au 10e tapotement. 1 bip indique 0 seconde, 2 bips indiquent 0,5 seconde, 3 bips indiquent 1 seconde, et 4 bips indiquent 1,5 seconde.

These functions are only adjustable within 10 minutes from start-up.

Adjusting sparkling water flow rate

NOTE: Sparkling water flow rate factory setting = 1.8L (0.4 Gal) per minute MAX. This may need adjusting depending on inlet pressure. To do so follow below steps:

1

Remove the 2 screws holding the top panel down and slide it off.

2

Localisez le régulateur de débit, il se trouve vers l'avant de l'appareil.

3

Le débit peut ensuite être ajusté comme suit : tourner le bouchon dans le sens antihoraire pour augmenter le débit et dans le sens horaire pour le restreindre. Après chaque ajustement, le débit doit être chronométré pour atteindre un débit acceptable et/ou une distribution pétillante ininterrompue.

4

Once the correct flow rate is achieved place the top panel back on to the unit by sliding it in place and replacing the screws.

Sparkling models only

Advanced troubleshooting

Troubleshooting

Défaut/Problème

Cause possible

Action suggérée

Pas de distribution d'eau

Alimentation coupée (icônes sur le panneau tactile éteintes)

Vérifiez que l'alimentation est correctement installée et allumée.

Eau isolée de l'unité

Vérifiez que l'arrivée d'eau est ouverte.

Réservoir refroidi congelé

Laissez l'appareil décongeler et inspectez-le soigneusement pour vous assurer qu'il n'est pas endommagé. Aucune fuite d'eau ne doit toucher l'interrupteur principal ou le connecteur d'entrée secteur.

Pas d'eau pétillante

Pas de pression CO2

Vérifiez la bouteille de CO2, le régulateur et la valve anti-retour. La pression d'alimentation doit être de 58 psi (4 bar), remplacez-les si nécessaire.

Le réservoir du carbonateur ne se remplit pas

Vérifiez la sonde du carbonateur pour un éventuel court-circuit à la terre.
Vérifiez le délai d'attente de la pompe, coupez puis remettez l'alimentation, puis purgez le carbonateur.

Carbonatation de mauvaise qualité

Pression de CO2 incorrecte

Vérifiez la bouteille de CO2, le régulateur et la valve anti-retour. La pression d'alimentation doit être de 58 psi (4 bar), remplacez-les si nécessaire.

Air dans le réservoir du carbonateur

Purger le réservoir du carbonateur. Suivez les instructions ci-dessous.

Résidu dans le réservoir du carbonateur

Après une utilisation prolongée, un film de surface peut se former à l'intérieur du réservoir du carbonateur. Reportez-vous aux instructions de nettoyage et de désinfection.

Boissons non réfrigérées

Flux d'air de refroidissement insuffisant autour du ProCore®

Vérifiez que le condenseur n'est pas bloqué. Vérifiez que les ventilateurs de refroidissement fonctionnent.
Assurez-vous que les exigences de ventilation ont été respectées.

Compresseur en panne

Vérifiez l'alimentation électrique du compresseur (tension secteur).
Vérifiez que la sonde NTC n'est pas défectueuse.
Vérifiez que la sonde NTC du DryBlock est connectée aux deux extrémités.
Vérifiez une surchauffe du système. Laissez l'appareil refroidir et vérifiez les obstructions du flux d'air. Une fois l'appareil refroidi, le système de refroidissement redémarrera. Si le problème persiste, contactez le support technique.

Panne du refroidisseur

Si le compresseur et le ventilateur fonctionnent mais qu'il n'y a pas de refroidissement, contactez le support technique.

Eau stagnante au fond de la machine

Raccord d'eau à ajustement lâche

Contactez votre distributeur.

Sonde de niveau de carbonatation déconnectée

Assurez-vous de connecter le faisceau de câblage du niveau du carburateur à la sonde de niveau du réservoir de carbonatation.

Tous les symboles ne s'affichent pas sur le panneau de contrôle

Solénoïde non connecté ou enroulement interne endommagé

Vérifiez la connexion du câblage au solénoïde et mesurez la résistance du solénoïde.

Water dripping from outlet

Solenoid valve not closing properly

Check solenoid and clean or replace if necessary.

Distribution continue ou incorrecte

Excès d'eau sur la lentille du panneau de contrôle

Assurez-vous de garder l'objectif propre et exempt de liquides.

Objectif HMI mal positionné sur le panneau de contrôle

Contacter le support technique ici.

Mauvais écoulement laminaire ou éclaboussures à la sortie

Dépôt de calcaire obstruant la sortie

Remplacer l'ensemble de la prise.

Warning flash sequences

In the event of the warning triangle flashing please see the sequences below for diagnostics.

Surchauffe interne déclenchée
Surchauffe due à une installation incorrecte de la ventilation.

Temps d'arrêt maximal du compresseur
Le compresseur ne peut pas atteindre la température de consigne.
Manque de gaz de réfrigération, fuite,
surutilisation, température de l'eau d'entrée trop élevée.

Délai d'attente de la pompe
La pompe à eau pétillante ne remplit pas correctement le carbonateur.
Aucune alimentation en eau vers l'appareil, la pompe à eau pétillante est défaillante.

Kit de déchets plein
Réservoir de débordement des déchets vide.

Emptying sparkling water

1

Coupez l'alimentation en eau.

2

Appuyez et maintenez le bouton de distribution d'eau pétillante jusqu'à ce que toute l'eau soit expulsée et que seul le gaz CO2 soit libéré.

3

The tank is empty of sparkling water when only CO2 is being released and no water is emitted.

4

Veillez à relâcher le bouton de l'eau pétillante et faites attention à ne pas libérer une quantité excessive de gaz CO2, car cela pourrait endommager le réservoir.

Technical information

T2 Chilled & Ambient circuit schematic

T2 Chilled & Sparkling circuit schematic

T2 Chilled, Sparkling & Ambient circuit schematic

T2 Chilled & Ambient water pathway

T2 Chilled & Sparkling Water Pathway

T2 Chilled, Sparkling & Ambient Water Pathway

Spares

ProCore exploded parts diagram

T2 exploded parts diagram

Safety critical spares

Part no.
Description
CA
CS
CSA
720023
Sonde de température
702787
Métier à tisser solénoïde du Congrès
702878
Faisceau de capteurs tout-en-un avec connecteurs KK
720295
Panneau de commande tactile (IHM) E6 pour la réfrigération et l'ambiance
720292
Ensemble de panneau de commande tactile (IHM) T2 Chilled & Sparkling
720289
Ensemble de panneau de commande tactile (IHM) E6 pour boissons fraîches, pétillantes et ambiantes
462667
Clapet anti-retour simple 5/16" (8 mm) PF
462668
Clapet anti-retour simple 1/4" à emboîtement
701094
Solénoïde 3/4” BSP 8 mm PF
703237
Solenoid 3/4” BSP 8mm UL
701937
Électrovanne de distribution 2:1 8 mm
703235
2:1 Dispense Solenoid Valve 8mm UL
701992
Électrovanne de distribution 3:1 8 mm
703236
3:1 Dispense Solenoid Valve 8mm UL
720337
Assemblage de la carte de commande principale PCBA
702800
Pompe de surpression à membrane - Pompe à eau pétillante à faible débit 115 V
702770
Pompe de surpression à membrane - Pompe à eau pétillante à faible débit 230 V
702558
Ventilateur de refroidissement 24 V avec métier à tisser
702078
Interrupteur de débit FS-16

Cosmetic spares

Part no.
Description
CA
CS
CSA
720411
Grille de bac d'égouttage série T et E7 - Acier poli
720450
Grille de bac d'égouttage série T et E7 - Plaqué noir
701453
Sortie de robinet T2 - Acier inoxydable plaqué noir
720112
Sortie de robinet T2 - Acier inoxydable poli
700092
Sortie à flux laminaire adaptée aux T1/T2
720045
Assemblage de porte ProCore complet
720113
Panneau latéral gauche du ProCore
720117
Panneau latéral droit du ProCore
700721
Panneau supérieur (VMI)

Contact support for any required spares not listed above.

Tous les composants doivent être remplacés par un technicien agréé par l'usine avec des composants approuvés par le fabricant (listés ci-dessus), afin de minimiser les risques pour la santé et la sécurité liés aux dangers électriques et au risque d'incendie dus à des pièces incorrectes ou à un service inapproprié.