1. Power off and remove the mains power plug of the ProCore.
2. Remove the top and front cover

Description

3. Remove and retain the 4 screws securing the old main control PCB.

Description

4. Secure the replacement PCB in its place and in the orientation pictured.

Description

5. Take the NTC Chiller connector on the old PCB and connect it to the C NTC connection on the new PCB.

Description

6. If a SPARKLING model remove and discard the carbonation level sensor from the PCB and the carbonation tank and connect the one provided to the new PCB connection ‘LEVEL’ and back to the carbonation tank Connect the sparkling jumper provided as shown

Description

7. Take the HMI Interface connector from the old PCB and connect it to the new PCB.

Description

8. When connecting the solenoid wires ensure the correct positioning:

 OLD PCB NEW PCB
AMBI SOL-A
CHILLED SOL-C
SPARKL SOL-S
INLET SOL-I
Description

9. Connect the High Voltage wires to the corresponding connectors on the new PC:

 OLD PCB NEW PCB
FAN AC FAN
COMPRESSOR COMPRESSOR
PUMP PUMP
AC POWER IN AC POWER IN
Description

10. Check if the connections are correct and secure, then power up the unit.